    User name apar

    Log entry time 01:39:00 on December 3, 2009

    Entry number 304258

    keyword=End_of_Parity_Run_14378__CODA_Config=Pvdis
    ************************************************
     Run Number: 14378
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production 110uA,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=14.0,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14378 at Thu Dec  3 01:38:54 EST 2009
    CODA Configuration: Pvdis
    
    
    
    Compton Run Number                       : 21363
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1730
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 81
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.119
    Gun2: PC (PITA) NEG                      : 6.581
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.74847
    Pockels Cell Voltage NEG                 : 1.5409
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 371.2
    Photodiode on table                      : 383.101
    Laser X position on QPD 1                : 90.2863
    Laser Y position on QPD 1                : 533.397
    Laser X position on QPD 2                : 30.9326
    Laser Y position on QPD 2                : -605.962
    QPD 1 sum                                : -1.25374
    QPD 2 sum                                : -1.15974
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -3350[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1409
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.83196
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.68
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 4.66764
    Calculated polarisation in cavity        : 97.8282
    Photodiode 1 after Wollaston prism       : 0.318581
    Photodiode 2 after Wollaston prism       : 0.00655464
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.64
    Left Arm Q1 momentum                     : 3.66015
    Left Arm Q1 gauss meter                  : -0.23214
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.81
    Left Arm Q2 momentum                     : 3.65957
    Left Arm Q2 gauss meter                  : 0.8273
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1321.52
    Left Arm D1 momentum                     : 3.65992
    Left Arm D1 NMR                          : 1.35571
    Left Arm Q3 power supply current         : 1457.3
    Left Arm Q3 momentum                     : 3.66046
    Left Arm Q3 gauss meter                  : -0.73482
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.43
    Right Arm Q1 momentum                    : 2.62979
    Right Arm Q1 gauss meter                 : -0.04912
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.95
    Right Arm Q2 momentum                    : 2.63019
    Right Arm Q2 gauss meter                 : 0.5921
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.917
    Right Arm D1 momentum                    : 2.63002
    Right Arm D1 NMR                         : 0.975971
    Right Arm Q3 power supply current        : 1046.61
    Right Arm Q3 momentum                    : 2.63028
    Right Arm Q3 gauss meter                 : 0.4683
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 4.93916
    Current on Unser monitor                 : 24.3386
    Current on Upstream bcm                  : 4.81551
    Current on Downstream bcm                : 5.06281
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 5.00294
    Tiefenbach Hall A energy                 : 6067.34
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 1.09488
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0.0206868
    IPM1C12.YPOS                             : 0.175771
    IPM1H04A.XPOS                            : -0.718667
    IPM1H04A.YPOS                            : 0.0226577
    IPM1H04B.XPOS                            : -0.785662
    IPM1H04B.YPOS                            : 0.0802132
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.0206868
    Survey Y offset bpm12                     : 0.194916
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077690
    fan frequency loop 1                     : 60
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.45
    temperature loop 1-2                     : 21.99
    temperature loop 1-3                     : 22.3
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.0935
    pressure fill bottle H2                  : 25.4887
    pressure ballast H2                      : 25.0202
    pressure exhaust H2                      : 25.0446
    cryogen input temp                       : 218.6
    crogen return flow                       : 0.388331
     JT valve setting                        : -0.341797
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14378.log:
    
       Cumulative stats for 99750 events: 
       
       Events failing cut conditions:
       0         Low_beam  75630
       1        Beam_burp    344
       2          Evt_seq      0
       3         Pair_seq      1
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------