NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 21:22:36 on December 3, 2009
Entry number 304459
keyword=End_of_Parity_Run_14396__CODA_Config=Pvdis
************************************************
Run Number: 14396
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=15,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14396 at Thu Dec 3 21:22:30 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21387
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 215
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.15
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.71
Gun2: PC (PITA) NEG : 6.99
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75336
Pockels Cell Voltage NEG : 1.55067
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 725.398
Photodiode on table : 383.848
Laser X position on QPD 1 : 111.962
Laser Y position on QPD 1 : 521.827
Laser X position on QPD 2 : 14.2274
Laser Y position on QPD 2 : -618.48
QPD 1 sum : -1.29158
QPD 2 sum : -1.09138
Position set point for adjustable
mirror 1 (either x or y) : -1645[c]
Position set point for adjustable
mirror 2 (either x or y) : -2235[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2063
Polarisation in cavity : LEFT
Reflection photodiode : 0.401025
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.68
Slow locking signal sent to laser : 0.0970517
Fast locking signal sent to laser : 9.79125
Calculated polarisation in cavity : 97.8158
Photodiode 1 after Wollaston prism : 0.626078
Photodiode 2 after Wollaston prism : 56.7823
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.59
Left Arm Q1 momentum : 3.66007
Left Arm Q1 gauss meter : -0.23209
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.79
Left Arm Q2 momentum : 3.65952
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1321.52
Left Arm D1 momentum : 3.65991
Left Arm D1 NMR : 1.35571
Left Arm Q3 power supply current : 1457.26
Left Arm Q3 momentum : 3.66037
Left Arm Q3 gauss meter : -0.73467
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.81
Right Arm Q1 momentum : 2.63029
Right Arm Q1 gauss meter : -0.04912
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.94
Right Arm Q2 momentum : 2.63016
Right Arm Q2 gauss meter : 0.5921
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.856
Right Arm D1 momentum : 2.63003
Right Arm D1 NMR : 0.975974
Right Arm Q3 power supply current : 1046.58
Right Arm Q3 momentum : 2.63021
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 97.9741
Current on Unser monitor : 116.747
Current on Upstream bcm : 95.8063
Current on Downstream bcm : 100.142
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 98.8937
Tiefenbach Hall A energy : 6067.35
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0980726
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0178892
IPM1C12.YPOS : 0.13154
IPM1H04A.XPOS : -0.688912
IPM1H04A.YPOS : 0.0529187
IPM1H04B.XPOS : -0.688941
IPM1H04B.YPOS : 0.0686201
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.00257769
Survey Y offset bpm12 : 0.140806
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077690
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.59
temperature loop 1-2 : 21.98
temperature loop 1-3 : 22.54
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 24.8325
pressure fill bottle H2 : 25.5802
pressure ballast H2 : 25.3086
pressure exhaust H2 : 25.0553
cryogen input temp : 218.8
crogen return flow : 0
JT valve setting : -0.341797
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14396.log:
Cumulative stats for 99869 events:
Events failing cut conditions:
0 Low_beam 12597
1 Beam_burp 254
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------