User name apar
Log entry time 23:12:29 on December 3, 2009
Entry number 304487
keyword=End_of_Parity_Run_14399__CODA_Config=Pvdis
************************************************
Run Number: 14399
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=15,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14399 at Thu Dec 3 23:12:19 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 226
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.15
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.801
Gun2: PC (PITA) NEG : 6.899
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75336
Pockels Cell Voltage NEG : 1.55067
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : 0.000000000000000e+00
Calculated power in cavity : 0.565721
Photodiode on table : 0
Laser X position on QPD 1 : 109.893
Laser Y position on QPD 1 : 523.899
Laser X position on QPD 2 : 13.8404
Laser Y position on QPD 2 : -615.81
QPD 1 sum : -1.32576
QPD 2 sum : -1.12189
Position set point for adjustable
mirror 1 (either x or y) : 0.000000000000000e+00
Position set point for adjustable
mirror 2 (either x or y) : 0.000000000000000e+00
Laser minimum temperature (35.8) : 32.2
Laser temperature set point : 0.000000000000000e+00
Polarisation in cavity : LEFT
Reflection photodiode : 0.869804
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -6.60868
Calculated polarisation in cavity : 13.534
Photodiode 1 after Wollaston prism : 0.0224364
Photodiode 2 after Wollaston prism : 0.0193302
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.64
Left Arm Q1 momentum : 3.66007
Left Arm Q1 gauss meter : -0.23211
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.79
Left Arm Q2 momentum : 3.65952
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1321.52
Left Arm D1 momentum : 3.6599
Left Arm D1 NMR : 1.35571
Left Arm Q3 power supply current : 1457.26
Left Arm Q3 momentum : 3.66037
Left Arm Q3 gauss meter : -0.73471
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.86
Right Arm Q1 momentum : 2.63029
Right Arm Q1 gauss meter : -0.04913
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.94
Right Arm Q2 momentum : 2.63016
Right Arm Q2 gauss meter : 0.592
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.857
Right Arm D1 momentum : 2.63003
Right Arm D1 NMR : 0.975974
Right Arm Q3 power supply current : 1046.58
Right Arm Q3 momentum : 2.63021
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 98.8618
Current on Unser monitor : 117.374
Current on Upstream bcm : 96.6037
Current on Downstream bcm : 100.522
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 99.7054
Tiefenbach Hall A energy : 6067.37
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0979514
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.00130841
IPM1C12.YPOS : 0.153184
IPM1H04A.XPOS : -0.70762
IPM1H04A.YPOS : 0.0189424
IPM1H04B.XPOS : -0.710808
IPM1H04B.YPOS : 0.0379502
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.00599691
Survey Y offset bpm12 : 0.153184
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077690
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.53
temperature loop 1-2 : 21.98
temperature loop 1-3 : 22.54
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 24.9393
pressure fill bottle H2 : 25.687
pressure ballast H2 : 25.2415
pressure exhaust H2 : 25.0202
cryogen input temp : 218.8
crogen return flow : 0.146104
JT valve setting : -0.439453
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14399.log:
Cumulative stats for 11734 events:
Events failing cut conditions:
0 Low_beam 1189
1 Beam_burp 28
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------