User name apar
Log entry time 23:02:47 on December 4, 2009
Entry number 304728
keyword=Start_Parity_Run_14414__CODA_Config=Pvdis_Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
Beginning-of-Parity-run EPICS data for Run Number 14414 at Fri Dec 4 23:01:48 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21399
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 222
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.15
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.063
Gun2: PC (PITA) NEG : 6.637
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75092
Pockels Cell Voltage NEG : 1.54823
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 747.759
Photodiode on table : 384.098
Laser X position on QPD 1 : 111.55
Laser Y position on QPD 1 : 523.814
Laser X position on QPD 2 : 14.2593
Laser Y position on QPD 2 : -619.569
QPD 1 sum : -1.27693
QPD 2 sum : -1.08893
Position set point for adjustable
mirror 1 (either x or y) : -1645[c]
Position set point for adjustable
mirror 2 (either x or y) : -1000[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1464
Polarisation in cavity : RIGHT
Reflection photodiode : 0.811207
Gain of locking servo : 131.122
Tracking level (V) of locking servo : 0.60975
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 5.49533
Calculated polarisation in cavity : 13.7333
Photodiode 1 after Wollaston prism : 0.0241499
Photodiode 2 after Wollaston prism : 0.0181146
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
Left S1 HV
S1 Slot1 ch0 : -1660.9
S1 Slot1 ch1 : -1785.3
S1 Slot1 ch2 : -1621.1
S1 Slot1 ch3 : -1676.5
S1 Slot1 ch4 : -1657.1
S1 Slot1 ch5 : -1870.7
S1 Slot1 ch6 : -1836.6
S1 Slot1 ch7 : -1675.6
S1 Slot1 ch8 : -1556.9
S1 Slot1 ch9 : -1621.1
S1 Slot1 ch10 : -1746.5
S1 Slot1 ch11 : -1760.6
-----
Left S2 HV Left PMTs
S2 Slot0 ch0 Left : -1639.8
S2 Slot0 ch1 Left : -1690.8
S2 Slot0 ch2 Left : -2015.9
S2 Slot0 ch3 Left : -1820.2
S2 Slot0 ch4 Left : -1858.4
S2 Slot0 ch5 Left : -1661.7
S2 Slot0 ch6 Left : -1836.8
S2 Slot0 ch7 Left : -1803.6
S2 Slot0 ch8 Left : -1795.8
S2 Slot0 ch9 Left : -1918.4
S2 Slot0 ch10 Left : -1975.6
S2 Slot0 ch11 Left : -1823.7
S2 Slot13 ch0 Left : -1954.5
S2 Slot13 ch1 Left : -2006.7
S2 Slot13 ch2 Left : -1776.6
S2 Slot13 ch3 Left : -1559.8
-----
Left S2 HV Right PMTs
S2 Slot12 ch0 Right : -1484.3
S2 Slot12 ch1 Right : -1627.6
S2 Slot12 ch2 Right : -1780.8
S2 Slot12 ch3 Right : -1699.9
S2 Slot12 ch4 Right : -1758
S2 Slot12 ch5 Right : -1731.7
S2 Slot12 ch6 Right : -1765.1
S2 Slot12 ch7 Right : -1472.1
S2 Slot12 ch8 Right : -1825.3
S2 Slot12 ch9 Right : -1700
S2 Slot12 ch10 Right : -1829.3
S2 Slot12 ch11 Right : -1550.9
S2 Slot13 ch4 Right : -1553
S2 Slot13 ch5 Right : -1635.9
S2 Slot13 ch6 Right : -1650
S2 Slot13 ch7 Right : -1626.6
-----
Left Cerenkov HV
GCER Slot2 ch0 : -1522.3
GCER Slot2 ch1 : -1436.5
GCER Slot2 ch2 : -1511.2
GCER Slot2 ch3 : -1421.2
GCER Slot2 ch4 : -1766.4
GCER Slot2 ch5 : -1990.5
GCER Slot2 ch6 : -17.1
GCER Slot2 ch7 : -1724.8
GCER Slot2 ch8 : -1960.8
GCER Slot2 ch9 : -1519.7
GCER Slot2 ch10 : -1745.2
GCER Slot2 ch11 : -15.3
-----
Left Pion Rejector Layer 1 HV
PRL1 Slot3 ch0 : -900.3
PRL1 Slot3 ch1 : -815.1
PRL1 Slot3 ch2 : -931.9
PRL1 Slot3 ch3 : -985.8
PRL1 Slot3 ch4 : -787.1
PRL1 Slot3 ch5 : -886.9
PRL1 Slot3 ch6 : -1095
PRL1 Slot3 ch7 : -1012.6
PRL1 Slot3 ch8 : -834.9
PRL1 Slot3 ch9 : -816.1
PRL1 Slot3 ch10 : -886.6
PRL1 Slot3 ch11 : -809.5
PRL1 Slot4 ch0 : -900.4
PRL1 Slot4 ch1 : -932.2
PRL1 Slot4 ch2 : -768.2
PRL1 Slot4 ch3 : -942
PRL1 Slot4 ch4 : -921.7
PRL1 Slot4 ch5 : -901.3
PRL1 Slot4 ch6 : -920.2
PRL1 Slot4 ch7 : -795.7
PRL1 Slot4 ch8 : -883.2
PRL1 Slot4 ch9 : -810.7
PRL1 Slot4 ch10 : -911.3
PRL1 Slot4 ch11 : -851.5
PRL1 Slot5 ch0 : -885.9
PRL1 Slot5 ch1 : -829.7
PRL1 Slot5 ch2 : -778.7
PRL1 Slot5 ch3 : -836.2
PRL1 Slot5 ch4 : -840.9
PRL1 Slot5 ch5 : -755.2
PRL1 Slot5 ch6 : -800.4
PRL1 Slot5 ch7 : -860.3
PRL1 Slot5 ch8 : -881.3
PRL1 Slot5 ch9 : -968.3
PRL1 Slot5 ch10 : -5
PRL1 Slot5 ch11 : -14.9
-----
Left Pion Rejector Layer 2 HV
PRL2 Slot9 ch0 : -804.7
PRL2 Slot9 ch1 : -796.3
PRL2 Slot9 ch2 : -820.8
PRL2 Slot9 ch3 : -772.6
PRL2 Slot9 ch4 : -720.6
PRL2 Slot9 ch5 : -901
PRL2 Slot9 ch6 : -795.8
PRL2 Slot9 ch7 : -990.2
PRL2 Slot9 ch8 : -924.2
PRL2 Slot9 ch9 : -865.2
PRL2 Slot9 ch10 : -1080.7
PRL2 Slot9 ch11 : -1054.4
PRL2 Slot10 ch0 : -806.2
PRL2 Slot10 ch1 : -861.3
PRL2 Slot10 ch2 : -1009.7
PRL2 Slot10 ch3 : -904.5
PRL2 Slot10 ch4 : -864.8
PRL2 Slot10 ch5 : -825.6
PRL2 Slot10 ch6 : -838.1
PRL2 Slot10 ch7 : -829.4
PRL2 Slot10 ch8 : -1190.4
PRL2 Slot10 ch9 : -1041.2
PRL2 Slot10 ch10 : -1081.1
PRL2 Slot10 ch11 : -836.5
PRL2 Slot11 ch0 : -1075.5
PRL2 Slot11 ch1 : -900.4
PRL2 Slot11 ch2 : -946.3
PRL2 Slot11 ch3 : -765.8
PRL2 Slot11 ch4 : -914.8
PRL2 Slot11 ch5 : -823.8
PRL2 Slot11 ch6 : -839
PRL2 Slot11 ch7 : -890.5
PRL2 Slot11 ch8 : -785.9
PRL2 Slot11 ch9 : -840.6
PRL2 Slot11 ch10 : -2.9
PRL2 Slot11 ch11 : -11.7
-----
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1978.34
Left Arm Q1 momentum : 2.62961
Left Arm Q1 gauss meter : -0.16683
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1132.5
Left Arm Q2 momentum : 2.63005
Left Arm Q2 gauss meter : 0.5956
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 908.441
Left Arm D1 momentum : 2.63004
Left Arm D1 NMR : 0.97356
Left Arm Q3 power supply current : 1047.08
Left Arm Q3 momentum : 2.63007
Left Arm Q3 gauss meter : -0.52836
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.86
Right Arm Q1 momentum : 2.63036
Right Arm Q1 gauss meter : -0.04915
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.93
Right Arm Q2 momentum : 2.63016
Right Arm Q2 gauss meter : 0.5921
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.856
Right Arm D1 momentum : 2.63
Right Arm D1 NMR : 0.975961
Right Arm Q3 power supply current : 1046.58
Right Arm Q3 momentum : 2.63021
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.51367
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.9043
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.0107422
Right Arm Bottom VDC voltage : -0.0112305
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 98.8572
Current on Unser monitor : 117.65
Current on Upstream bcm : 95.8001
Current on Downstream bcm : 99.9123
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 99.8662
Tiefenbach Hall A energy : 6067.4
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.170272
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.00776082
IPM1C12.YPOS : 0.149287
IPM1H04A.XPOS : -0.714913
IPM1H04A.YPOS : 0.0274054
IPM1H04B.XPOS : -0.720105
IPM1H04B.YPOS : 0.0457401
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.00776082
Survey Y offset bpm12 : 0.149287
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.619922
HacL_HPE1313A:0_Ch58 : -0.166016
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : -0.168945
Left Arm Angle Floor Angle : 20
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 19.9997
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -4.88281e-05
HacR_HPE1313A:0_Ch58 : -0.599609
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.927246
Right Arm Angle Floor Angle : 20
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 20.001
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077690
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.78
temperature loop 1-2 : 22
temperature loop 1-3 : 22.56
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.1423
pressure fill bottle H2 : 25.8152
pressure ballast H2 : 25.2262
pressure exhaust H2 : 25.51
cryogen input temp : 218.4
crogen return flow : 0.441991
JT valve setting : -0.244141
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
anatype fdbk
curmon bcm1
feedback PITA on 1 bcm1
feedback IA off 1 bcm1
IAHallCparam slope 200.0
IAparam slope 1.0
PITAparam slope 21202
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Low_beam_c
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 1 1200
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 14414 -d '2009-12-04 23:01:44' -t 33077690 -s IN