• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 13:27:33 on December 7, 2009

    Entry number 305350

    keyword=End_of_Parity_Run_14485__CODA_Config=Pvdis
    ************************************************
     Run Number: 14485
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=Production,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14485 at Mon Dec  7 13:25:06 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       :  compton:RUN --- Invalid channel name
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1730
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 65
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.1
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.014
    Gun2: PC (PITA) NEG                      : 6.686
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00977
    Pockels Cell Voltage NEG                 : 1.83394
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              :  COMPTON_LASERP_si --- Invalid channel name
    Calculated power in cavity               :  COMPTON_PW1PCAV_ca --- Invalid channel name
    Photodiode on table                      :  COMPTON_PW2PCAV_ca --- Invalid channel name
    Laser X position on QPD 1                :  COMPTON_Y1SS_ca --- Invalid channel name
    Laser Y position on QPD 1                :  COMPTON_X1SS_ca --- Invalid channel name
    Laser X position on QPD 2                :  COMPTON_Y2SS_ca --- Invalid channel name
    Laser Y position on QPD 2                :  COMPTON_X2SS_ca --- Invalid channel name
    QPD 1 sum                                :  COMPTON_XYSUM1_ca --- Invalid channel name
    QPD 2 sum                                :  COMPTON_XYSUM2_ca --- Invalid channel name
    Position set point for adjustable 
                   mirror 1 (either x or y)  :  COMPTON_POS1_si --- Invalid channel name
    Position set point for adjustable 
                   mirror 2 (either x or y)  :  COMPTON_POS3_si --- Invalid channel name
    Laser minimum temperature (35.8)         :  COMPTON_LASERT_MIN --- Invalid channel name
    Laser temperature set point              :  COMPTON_LASERT_si --- Invalid channel name
    Polarisation in cavity                   :  COMPTON_SU_POLAR_mo --- Invalid channel name
    Reflection photodiode                    :  COMPTON_SERVO_PDRai --- Invalid channel name
    Gain of locking servo                    :  COMPTON_SERVO_GAINao --- Invalid channel name
    Tracking level (V) of locking servo      :  COMPTON_SERVO_SEUILao --- Invalid channel name
    Slow locking signal sent to laser        :  COMPTON_SERVO_SLOWai --- Invalid channel name
    Fast locking signal sent to laser        :  COMPTON_SERVO_FASTai --- Invalid channel name
    Calculated polarisation in cavity        :  COMPTON_CAVPOLAR_ca --- Invalid channel name
    Photodiode 1 after Wollaston prism       :  COMPTON_PW1R_S1_ca --- Invalid channel name
    Photodiode 2 after Wollaston prism       :  COMPTON_PW1R_S2_ca --- Invalid channel name
    Step size for RHWP scan                  :  COMPTON_PVAL_Y_ao --- Invalid channel name
    Laser temp slow ramp (1 = on)            :  COMPTON_CAVSLOW_bo --- Invalid channel name
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         :  COMPTON_CAVPLUSOFT_ca.B --- Invalid channel name
    Speed of laser temp slow ramp down       :  COMPTON_CAVMOINSOFT_ca.B --- Invalid channel name
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 1978.61
    Left Arm Q1 momentum                     : 2.63004
    Left Arm Q1 gauss meter                  : -0.16684
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1132.5
    Left Arm Q2 momentum                     : 2.63004
    Left Arm Q2 gauss meter                  : 0.5955
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 908.441
    Left Arm D1 momentum                     : 2.63004
    Left Arm D1 NMR                          : 0.973561
    Left Arm Q3 power supply current         : 1047.09
    Left Arm Q3 momentum                     : 2.63011
    Left Arm Q3 gauss meter                  : -0.52832
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.86
    Right Arm Q1 momentum                    : 2.63036
    Right Arm Q1 gauss meter                 : -0.04913
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.94
    Right Arm Q2 momentum                    : 2.63017
    Right Arm Q2 gauss meter                 : 0.5921
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.857
    Right Arm D1 momentum                    : 2.62997
    Right Arm D1 NMR                         : 0.975952
    Right Arm Q3 power supply current        : 1046.6
    Right Arm Q3 momentum                    : 2.63024
    Right Arm Q3 gauss meter                 : 0.4683
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0324363
    Current on Unser monitor                 : 20.7469
    Current on Upstream bcm                  : 0.0400636
    Current on Downstream bcm                : 0.0248456
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.376596
    Tiefenbach Hall A energy                 : 6067.46
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.0590268
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Clear
    Encoder position                         : 33077692
    fan frequency loop 1                     : 59.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.26
    temperature loop 1-2                     : 22
    temperature loop 1-3                     : 22.29
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 25.3193
    pressure fill bottle H2                  : 25.9281
    pressure ballast H2                      : 25.0324
    pressure exhaust H2                      : 25.5177
    cryogen input temp                       : 216.9
    crogen return flow                       : 0.380727
     JT valve setting                        : -0.244141
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14485.log:
    
       Cumulative stats for 4605 events: 
       
       Events failing cut conditions:
       0         Low_beam   1795
       1        Beam_burp      3
       2          Evt_seq      0
       3         Pair_seq      0
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------