User name apar
Log entry time 05:34:00 on December 8, 2009
Entry number 305542
keyword=End_of_Parity_Run_14509__CODA_Config=Pvdis
************************************************
Run Number: 14509
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=Production,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14509 at Tue Dec 8 05:33:54 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21451
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 229
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.1
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.933
Gun2: PC (PITA) NEG : 6.767
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01221
Pockels Cell Voltage NEG : 1.83883
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 811.67
Photodiode on table : 390.329
Laser X position on QPD 1 : 107.745
Laser Y position on QPD 1 : 526.299
Laser X position on QPD 2 : 13.4417
Laser Y position on QPD 2 : -626.006
QPD 1 sum : -1.28182
QPD 2 sum : -1.07551
Position set point for adjustable
mirror 1 (either x or y) : -1645[c]
Position set point for adjustable
mirror 2 (either x or y) : -1000[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1339
Polarisation in cavity : RIGHT
Reflection photodiode : 0.432766
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.265519
Fast locking signal sent to laser : -0.357078
Calculated polarisation in cavity : 98.0122
Photodiode 1 after Wollaston prism : 64.838
Photodiode 2 after Wollaston prism : 0.650387
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1978.77
Left Arm Q1 momentum : 2.63018
Left Arm Q1 gauss meter : -0.16686
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1132.49
Left Arm Q2 momentum : 2.63003
Left Arm Q2 gauss meter : 0.5955
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 908.442
Left Arm D1 momentum : 2.63004
Left Arm D1 NMR : 0.973562
Left Arm Q3 power supply current : 1047.08
Left Arm Q3 momentum : 2.63007
Left Arm Q3 gauss meter : -0.52831
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.86
Right Arm Q1 momentum : 2.63036
Right Arm Q1 gauss meter : -0.04913
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.93
Right Arm Q2 momentum : 2.63014
Right Arm Q2 gauss meter : 0.5921
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.855
Right Arm D1 momentum : 2.63002
Right Arm D1 NMR : 0.975969
Right Arm Q3 power supply current : 1046.58
Right Arm Q3 momentum : 2.6302
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 53.7032
Current on Unser monitor : 67.2575
Current on Upstream bcm : 46.1546
Current on Downstream bcm : 61.2518
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 59.658
Tiefenbach Hall A energy : 6068
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 3.97702
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.371792
IPM1C12.YPOS : 0.130952
IPM1H04A.XPOS : -0.709703
IPM1H04A.YPOS : -0.0388138
IPM1H04B.XPOS : -0.661944
IPM1H04B.YPOS : -0.0557073
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.108978
Survey Y offset bpm12 : 0.141358
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Clear
Encoder position : 33077692
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.49
temperature loop 1-2 : 22.02
temperature loop 1-3 : 22.49
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.1408
pressure fill bottle H2 : 25.9052
pressure ballast H2 : 24.506
pressure exhaust H2 : 25.3742
cryogen input temp : 216.7
crogen return flow : 0
JT valve setting : -0.0976562
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_14509.log