User name apar
Log entry time 23:19:39 on December 9, 2009
Entry number 305870
keyword=End_of_Parity_Run_14539__CODA_Config=Pvdis
************************************************
Run Number: 14539
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=Right-Q3 off,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14539 at Wed Dec 9 23:19:33 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21510
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 139
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.1
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.763
Gun2: PC (PITA) NEG : 6.937
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.74847
Pockels Cell Voltage NEG : 1.54579
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.556013
Photodiode on table : 385.842
Laser X position on QPD 1 : 112.722
Laser Y position on QPD 1 : 523.565
Laser X position on QPD 2 : 13.2908
Laser Y position on QPD 2 : -616.983
QPD 1 sum : -1.27083
QPD 2 sum : -1.08771
Position set point for adjustable
mirror 1 (either x or y) : -1645[c]
Position set point for adjustable
mirror 2 (either x or y) : -1000[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.3129
Polarisation in cavity : LEFT
Reflection photodiode : 0.83196
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -6.61234
Calculated polarisation in cavity : 17.7392
Photodiode 1 after Wollaston prism : 0.0253815
Photodiode 2 after Wollaston prism : 0.0177333
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1978.87
Left Arm Q1 momentum : 2.63032
Left Arm Q1 gauss meter : -0.16689
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1132.47
Left Arm Q2 momentum : 2.62999
Left Arm Q2 gauss meter : 0.5956
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 908.446
Left Arm D1 momentum : 2.63005
Left Arm D1 NMR : 0.973567
Left Arm Q3 power supply current : 1047.1
Left Arm Q3 momentum : 2.63012
Left Arm Q3 gauss meter : -0.52832
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.91
Right Arm Q1 momentum : 2.63043
Right Arm Q1 gauss meter : -0.04914
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.94
Right Arm Q2 momentum : 2.63016
Right Arm Q2 gauss meter : 0.5921
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.827
Right Arm D1 momentum : 2.62999
Right Arm D1 NMR : 0.975956
Right Arm Q3 power supply current : 0.0942744
Right Arm Q3 momentum : 0.00247677
Right Arm Q3 gauss meter : 0.0001425
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 106.806
Current on Unser monitor : 126.212
Current on Upstream bcm : 104.502
Current on Downstream bcm : 109.11
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 107.924
Tiefenbach Hall A energy : 6067.34
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 3.79024
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.00432518
IPM1C12.YPOS : 0.124434
IPM1H04A.XPOS : -0.767956
IPM1H04A.YPOS : 0.00567168
IPM1H04B.XPOS : -0.704206
IPM1H04B.YPOS : 0.0204062
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.00256792
Survey Y offset bpm12 : 0.118569
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.57
temperature loop 1-2 : 22
temperature loop 1-3 : 22.6
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.0263
pressure fill bottle H2 : 25.7221
pressure ballast H2 : 25.478
pressure exhaust H2 : 25.1026
cryogen input temp : 216.5
crogen return flow : 0.353669
JT valve setting : -0.634766
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14539.log:
Cumulative stats for 99750 events:
Events failing cut conditions:
0 Low_beam 19010
1 Beam_burp 273
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------