NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 16:29:31 on December 14, 2009
Entry number 307002
keyword=End_of_Parity_Run_14661__CODA_Config=Pvdis
************************************************
Run Number: 14661
End of Run Comment:
Run_type=Test,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=Boiling test, 115uA, 50Hz, 2x2, LD2 target,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 14661 at Mon Dec 14 16:29:25 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 183
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.789
Gun2: PC (PITA) NEG : 6.911
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99023
Pockels Cell Voltage NEG : 1.83639
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 507.377
Photodiode on table : 394.566
Laser X position on QPD 1 : 82.3051
Laser Y position on QPD 1 : 539.799
Laser X position on QPD 2 : 21.4066
Laser Y position on QPD 2 : -616.976
QPD 1 sum : -1.23054
QPD 2 sum : -1.12556
Position set point for adjustable
mirror 1 (either x or y) : -3375[c]
Position set point for adjustable
mirror 2 (either x or y) : -520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1450
Polarisation in cavity : RIGHT
Reflection photodiode : 0.56583
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : -0.412013
Fast locking signal sent to laser : 4.72258
Calculated polarisation in cavity : 97.7762
Photodiode 1 after Wollaston prism : 39.6573
Photodiode 2 after Wollaston prism : 0.445906
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1978.82
Left Arm Q1 momentum : 2.63025
Left Arm Q1 gauss meter : -0.16685
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1132.47
Left Arm Q2 momentum : 2.62998
Left Arm Q2 gauss meter : 0.5955
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 908.448
Left Arm D1 momentum : 2.63008
Left Arm D1 NMR : 0.973577
Left Arm Q3 power supply current : 1047.09
Left Arm Q3 momentum : 2.63008
Left Arm Q3 gauss meter : -0.52828
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.86
Right Arm Q1 momentum : 2.63036
Right Arm Q1 gauss meter : -0.04913
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.94
Right Arm Q2 momentum : 2.63016
Right Arm Q2 gauss meter : 0.5921
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.828
Right Arm D1 momentum : 2.63
Right Arm D1 NMR : 0.975962
Right Arm Q3 power supply current : 1046.59
Right Arm Q3 momentum : 2.63023
Right Arm Q3 gauss meter : 0.4679
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 113.171
Current on Unser monitor : 131.795
Current on Upstream bcm : 110.645
Current on Downstream bcm : 115.697
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 114.148
Tiefenbach Hall A energy : 6067.04
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 5.13061
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 2
Raster Y width : 2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.205927
IPM1C12.YPOS : 0.0853277
IPM1H04A.XPOS : -0.772512
IPM1H04A.YPOS : -0.0083676
IPM1H04B.XPOS : -0.746947
IPM1H04B.YPOS : 0.0243935
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.205927
Survey Y offset bpm12 : 0.0853277
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077694
fan frequency loop 1 : 50.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.37
temperature loop 1-2 : 22
temperature loop 1-3 : 22.66
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.7267
pressure fill bottle H2 : 25.6062
pressure ballast H2 : 25.9739
pressure exhaust H2 : 25.2934
cryogen input temp : 216.2
crogen return flow : 0.191956
JT valve setting : -0.341797
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_14661.log