• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 18:27:53 on December 14, 2009

    Entry number 307037

    keyword=End_of_Parity_Run_14664__CODA_Config=Pvdis
    ************************************************
     Run Number: 14664
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14664 at Mon Dec 14 18:27:49 EST 2009
    CODA Configuration: Pvdis
    
    
    
    Compton Run Number                       : 21598
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1730
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 88
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.789
    Gun2: PC (PITA) NEG                      : 6.911
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2
    Pockels Cell Voltage NEG                 : 1.83639
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 0.233879
    Photodiode on table                      : 376.122
    Laser X position on QPD 1                : 99.0225
    Laser Y position on QPD 1                : 515.358
    Laser X position on QPD 2                : 16.0819
    Laser Y position on QPD 2                : -591.719
    QPD 1 sum                                : -1.25252
    QPD 2 sum                                : -1.0987
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -3405[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -680[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1568
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.812427
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.66
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : -0.0824026
    Calculated polarisation in cavity        : 2.25944
    Photodiode 1 after Wollaston prism       : 0.0111379
    Photodiode 2 after Wollaston prism       : 0.00903349
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 1978.82
    Left Arm Q1 momentum                     : 2.63018
    Left Arm Q1 gauss meter                  : -0.16685
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1132.47
    Left Arm Q2 momentum                     : 2.62998
    Left Arm Q2 gauss meter                  : 0.5956
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 908.448
    Left Arm D1 momentum                     : 2.63008
    Left Arm D1 NMR                          : 0.973578
    Left Arm Q3 power supply current         : 1047.09
    Left Arm Q3 momentum                     : 2.63009
    Left Arm Q3 gauss meter                  : -0.5283
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.86
    Right Arm Q1 momentum                    : 2.63036
    Right Arm Q1 gauss meter                 : -0.04912
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.93
    Right Arm Q2 momentum                    : 2.63016
    Right Arm Q2 gauss meter                 : 0.592
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.827
    Right Arm D1 momentum                    : 2.62999
    Right Arm D1 NMR                         : 0.975957
    Right Arm Q3 power supply current        : 1046.59
    Right Arm Q3 momentum                    : 2.63023
    Right Arm Q3 gauss meter                 : 0.4679
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 25.9095
    Current on Unser monitor                 : 43.7282
    Current on Upstream bcm                  : 25.2683
    Current on Downstream bcm                : 26.5508
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 26.0057
    Tiefenbach Hall A energy                 : 6067.98
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 4.89313
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0.0888349
    IPM1C12.YPOS                             : 0.0462979
    IPM1H04A.XPOS                            : -0.860152
    IPM1H04A.YPOS                            : -0.102835
    IPM1H04B.XPOS                            : -0.789925
    IPM1H04B.YPOS                            : -0.121135
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.0888349
    Survey Y offset bpm12                     : 0.0462979
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077694
    fan frequency loop 1                     : 59.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 23.44
    temperature loop 1-2                     : 21.96
    temperature loop 1-3                     : 22.32
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 25.6199
    pressure fill bottle H2                  : 25.4887
    pressure ballast H2                      : 25.9236
    pressure exhaust H2                      : 25.1637
    cryogen input temp                       : 216.3
    crogen return flow                       : 0
     JT valve setting                        : -0.488281
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14664.log:
    
       Cumulative stats for 99869 events: 
       
       Events failing cut conditions:
       0         Low_beam  16571
       1        Beam_burp    354
       2          Evt_seq      0
       3         Pair_seq      1
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------