NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 00:17:47 on December 17, 2009
Entry number 307549
keyword=End_of_Parity_Run_14717__CODA_Config=Pvdis
************************************************
Run Number: 14717
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14717 at Thu Dec 17 00:17:41 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21635
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 222
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.225
Gun2: PC (PITA) NEG : 6.475
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.67521
Pockels Cell Voltage NEG : 1.6337
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 783.206
Photodiode on table : 391.575
Laser X position on QPD 1 : 104.461
Laser Y position on QPD 1 : 525.55
Laser X position on QPD 2 : 16.9249
Laser Y position on QPD 2 : -620.054
QPD 1 sum : -1.34286
QPD 2 sum : -1.10725
Position set point for adjustable
mirror 1 (either x or y) : -3405[c]
Position set point for adjustable
mirror 2 (either x or y) : -2035[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1037
Polarisation in cavity : RIGHT
Reflection photodiode : 0.421779
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : -0.239883
Fast locking signal sent to laser : 7.69639
Calculated polarisation in cavity : 97.8646
Photodiode 1 after Wollaston prism : 61.2423
Photodiode 2 after Wollaston prism : 0.660946
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 1978.82
Left Arm Q1 momentum : 2.63025
Left Arm Q1 gauss meter : -0.16687
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1132.46
Left Arm Q2 momentum : 2.62997
Left Arm Q2 gauss meter : 0.5956
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 908.419
Left Arm D1 momentum : 2.63001
Left Arm D1 NMR : 0.973551
Left Arm Q3 power supply current : 1047.08
Left Arm Q3 momentum : 2.63007
Left Arm Q3 gauss meter : -0.5283
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.81
Right Arm Q1 momentum : 2.63029
Right Arm Q1 gauss meter : -0.04914
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.92
Right Arm Q2 momentum : 2.63012
Right Arm Q2 gauss meter : 0.592
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.83
Right Arm D1 momentum : 2.63003
Right Arm D1 NMR : 0.975974
Right Arm Q3 power supply current : 1046.58
Right Arm Q3 momentum : 2.63021
Right Arm Q3 gauss meter : 0.4679
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 103.697
Current on Unser monitor : 121.46
Current on Upstream bcm : 101.44
Current on Downstream bcm : 105.953
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 104.116
Tiefenbach Hall A energy : 6067.37
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 4.71688
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0119868
IPM1C12.YPOS : 0.0909141
IPM1H04A.XPOS : -0.736907
IPM1H04A.YPOS : 0.0233947
IPM1H04B.XPOS : -0.701577
IPM1H04B.YPOS : 0.0388246
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.0119868
Survey Y offset bpm12 : 0.0909141
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 23.21
temperature loop 1-2 : 21.99
temperature loop 1-3 : 22.57
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.4688
pressure fill bottle H2 : 25.5512
pressure ballast H2 : 25.5802
pressure exhaust H2 : 25.3178
cryogen input temp : 216.3
crogen return flow : 0
JT valve setting : -0.292969
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14717.log:
Cumulative stats for 99750 events:
Events failing cut conditions:
0 Low_beam 24756
1 Beam_burp 224
2 Evt_seq 0
3 Pair_seq 1
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------