NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 15:07:57 on December 17, 2009
Entry number 307671
keyword=End_of_Parity_Run_14733__CODA_Config=Pvdis
************************************************
Run Number: 14733
End of Run Comment:
Run_type=Cosmics,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=,dithering_magnet=on,dithering_magnets=,leftarm_p=2.63,leftarm_theta=20,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14733 at Thu Dec 17 15:07:52 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21644
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1730
Wien field : 49.796
Laser attenuation Hall A : 75
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.255
Gun2: PC (PITA) NEG : 6.445
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.74603
Pockels Cell Voltage NEG : 1.54335
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 570.526
Photodiode on table : 387.089
Laser X position on QPD 1 : 97.4187
Laser Y position on QPD 1 : 531.279
Laser X position on QPD 2 : 19.6162
Laser Y position on QPD 2 : -621.6
QPD 1 sum : -1.28426
QPD 2 sum : -1.06452
Position set point for adjustable
mirror 1 (either x or y) : -3405[c]
Position set point for adjustable
mirror 2 (either x or y) : -2035[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2145
Polarisation in cavity : RIGHT
Reflection photodiode : 0.508454
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 0.203259
Fast locking signal sent to laser : 0.877129
Calculated polarisation in cavity : 97.6881
Photodiode 1 after Wollaston prism : 44.5703
Photodiode 2 after Wollaston prism : 0.520868
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 3009.67
Left Arm Q1 momentum : 4.00046
Left Arm Q1 gauss meter : -0.25353
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.91
Left Arm Q2 momentum : 3.6598
Left Arm Q2 gauss meter : 0.8273
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1498.43
Left Arm D1 momentum : 3.99994
Left Arm D1 NMR : 1.48188
Left Arm Q3 power supply current : 1457.26
Left Arm Q3 momentum : 3.66038
Left Arm Q3 gauss meter : -0.7346
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 2331.36
Right Arm Q1 momentum : 3.10041
Right Arm Q1 gauss meter : -0.05784
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1334.13
Right Arm Q2 momentum : 3.09999
Right Arm Q2 gauss meter : 0.6974
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1118.93
Right Arm D1 momentum : 3.09998
Right Arm D1 NMR : 1.15037
Right Arm Q3 power supply current : 1233.48
Right Arm Q3 momentum : 3.09991
Right Arm Q3 gauss meter : 0.5519
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0330267
Current on Unser monitor : 18.8256
Current on Upstream bcm : 0.0401309
Current on Downstream bcm : 0.0259226
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00490315
Tiefenbach Hall A energy : 4869.55
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 4.29802
MBSY1c Hall A Beam energy : 4879.7
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 203.644
MBSY1c Bdl : 1.21774e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 3202549
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 23.68
temperature loop 1-2 : 21.98
temperature loop 1-3 : 22.3
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.4795
pressure fill bottle H2 : 25.6199
pressure ballast H2 : 25.922
pressure exhaust H2 : 25.4292
cryogen input temp : 216
crogen return flow : 0.384784
JT valve setting : -0.439453
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14733.log:
Cumulative stats for 99751 events:
Events failing cut conditions:
0 Low_beam 99751
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------