• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 07:31:21 on December 19, 2009

    Entry number 308114

    keyword=End_of_Parity_Run_14770__CODA_Config=Pvdis
    ************************************************
     Run Number: 14770
     End of Run Comment:
    
    Run_type=Production,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=4868,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14770 at Sat Dec 19 07:31:13 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 21670
    -----------------------------------------
    Wien angle                               : 90.4685
    Wien BDL                                 : 2098.1
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 201
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.802
    Gun2: PC (PITA) NEG                      : 6.898
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.01709
    Pockels Cell Voltage NEG                 : 1.83883
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 758.367
    Photodiode on table                      : 390.329
    Laser X position on QPD 1                : 162.848
    Laser Y position on QPD 1                : 485.245
    Laser X position on QPD 2                : -14.6494
    Laser Y position on QPD 2                : -605.944
    QPD 1 sum                                : -1.65293
    QPD 2 sum                                : -1.20613
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -2335[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -3805[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.3097
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.490142
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.66
    Slow locking signal sent to laser        : 0.0824024
    Fast locking signal sent to laser        : 6.29006
    Calculated polarisation in cavity        : 97.9393
    Photodiode 1 after Wollaston prism       : 59.419
    Photodiode 2 after Wollaston prism       : 0.617566
    Step size for RHWP scan                  : 11162
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 3009.67
    Left Arm Q1 momentum                     : 4.00046
    Left Arm Q1 gauss meter                  : -0.2534
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1576.06
    Left Arm Q2 momentum                     : 3.66015
    Left Arm Q2 gauss meter                  : 0.8273
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1498.43
    Left Arm D1 momentum                     : 3.99988
    Left Arm D1 NMR                          : 1.48186
    Left Arm Q3 power supply current         : 1457.2
    Left Arm Q3 momentum                     : 3.66022
    Left Arm Q3 gauss meter                  : -0.73459
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 2331.68
    Right Arm Q1 momentum                    : 3.1009
    Right Arm Q1 gauss meter                 : -0.05786
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1334.11
    Right Arm Q2 momentum                    : 3.09994
    Right Arm Q2 gauss meter                 : 0.6974
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1118.9
    Right Arm D1 momentum                    : 3.10004
    Right Arm D1 NMR                         : 1.15039
    Right Arm Q3 power supply current        : 1233.47
    Right Arm Q3 momentum                    : 3.09988
    Right Arm Q3 gauss meter                 : 0.5519
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 98.8195
    Current on Unser monitor                 : 118.585
    Current on Upstream bcm                  : 96.7764
    Current on Downstream bcm                : 100.863
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 99.0988
    Tiefenbach Hall A energy                 : 4867.39
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.582413
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 203.554
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.00256392
    IPM1C12.YPOS                             : -0.378088
    IPM1H04A.XPOS                            : -0.704028
    IPM1H04A.YPOS                            : -0.0324396
    IPM1H04B.XPOS                            : -0.702813
    IPM1H04B.YPOS                            : 0.0089069
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.00256392
    Survey Y offset bpm12                     : -0.378088
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077692
    fan frequency loop 1                     : 59.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 23.04
    temperature loop 1-2                     : 22
    temperature loop 1-3                     : 22.58
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 25.0858
    pressure fill bottle H2                  : 25.2186
    pressure ballast H2                      : 26.0182
    pressure exhaust H2                      : 25.0782
    cryogen input temp                       : 217
    crogen return flow                       : 0.185381
     JT valve setting                        : 0.0976562
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14770.log:
    
       Cumulative stats for 99750 events: 
       
       Events failing cut conditions:
       0         Low_beam  21064
       1        Beam_burp    282
       2          Evt_seq      0
       3         Pair_seq      0
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------