NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 13:12:04 on December 21, 2009
Entry number 308695
keyword=End_of_Parity_Run_14811__CODA_Config=Pvdis
************************************************
Run Number: 14811
End of Run Comment:
Run_type=Production,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=Production,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14811 at Mon Dec 21 13:11:58 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21693
-----------------------------------------
Wien angle : 90.4685
Wien BDL : 2098.1
Wien field : 60.306
Laser attenuation Hall A : 248
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.869
Gun2: PC (PITA) NEG : 6.831
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75336
Pockels Cell Voltage NEG : 1.54823
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 838.91
Photodiode on table : 390.08
Laser X position on QPD 1 : 164.402
Laser Y position on QPD 1 : 483.544
Laser X position on QPD 2 : -13.7338
Laser Y position on QPD 2 : -602.932
QPD 1 sum : -1.65049
QPD 2 sum : -1.20857
Position set point for adjustable
mirror 1 (either x or y) : -2335[c]
Position set point for adjustable
mirror 2 (either x or y) : 100[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2154
Polarisation in cavity : RIGHT
Reflection photodiode : 0.431545
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 1.14082
Fast locking signal sent to laser : 4.01941
Calculated polarisation in cavity : 97.9304
Photodiode 1 after Wollaston prism : 65.6171
Photodiode 2 after Wollaston prism : 0.686092
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2671.5
Left Arm Q1 momentum : 3.55089
Left Arm Q1 gauss meter : -0.22502
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1528.44
Left Arm Q2 momentum : 3.54956
Left Arm Q2 gauss meter : 0.8022
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1272.81
Left Arm D1 momentum : 3.55007
Left Arm D1 NMR : 1.31495
Left Arm Q3 power supply current : 1413
Left Arm Q3 momentum : 3.5492
Left Arm Q3 gauss meter : -0.7122
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 2331.41
Right Arm Q1 momentum : 3.10048
Right Arm Q1 gauss meter : -0.05786
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1334.08
Right Arm Q2 momentum : 3.09987
Right Arm Q2 gauss meter : 0.6974
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1118.44
Right Arm D1 momentum : 3.09998
Right Arm D1 NMR : 1.15036
Right Arm Q3 power supply current : 1233.66
Right Arm Q3 momentum : 3.10035
Right Arm Q3 gauss meter : 0.552
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 115.089
Current on Unser monitor : 133.257
Current on Upstream bcm : 112.072
Current on Downstream bcm : 118.106
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 115.019
Tiefenbach Hall A energy : 4867.36
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 1.32398
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 203.554
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.0196169
IPM1C12.YPOS : -0.34856
IPM1H04A.XPOS : -0.71599
IPM1H04A.YPOS : 0.0141508
IPM1H04B.XPOS : -0.696541
IPM1H04B.YPOS : 0.00677943
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.0161798
Survey Y offset bpm12 : -0.348309
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 23.21
temperature loop 1-2 : 22.02
temperature loop 1-3 : 22.66
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.362
pressure fill bottle H2 : 25.3101
pressure ballast H2 : 26.2226
pressure exhaust H2 : 25.0736
cryogen input temp : 220.4
crogen return flow : 0
JT valve setting : -0.439453
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14811.log:
Cumulative stats for 99869 events:
Events failing cut conditions:
0 Low_beam 17298
1 Beam_burp 285
2 Evt_seq 0
3 Pair_seq 1
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------