    User name apar

    Log entry time 15:51:36 on January 5, 2010

    Entry number 308958

    keyword=End_of_Parity_Run_1011__CODA_Config=Prex
    ************************************************
     Run Number: 1011
     End of Run Comment:
    
    Run_type=Production,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=DAQ test,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1011 at Tue Jan  5 15:51:29 EST 2010
    CODA Configuration: Prex
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 21805
    -----------------------------------------
    Wien angle                               : 0
    Wien BDL                                 : 3.18799
    Wien field                               : 60.306
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : -1
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.27
    Gun2: PC (PITA) NEG                      : 6.43
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.01709
    Pockels Cell Voltage NEG                 : 1.82418
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 31mW
    Calculated power in cavity               : 0.147979
    Photodiode on table                      : -0.0881854
    Laser X position on QPD 1                : -147.891
    Laser Y position on QPD 1                : -108.937
    Laser X position on QPD 2                : -438.65
    Laser Y position on QPD 2                : 442.478
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : 0.0012207
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -2335[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 100[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1418
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.051883
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.66
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : 6.65263
    Calculated polarisation in cavity        : 17.6663
    Photodiode 1 after Wollaston prism       : 0.00655957
    Photodiode 2 after Wollaston prism       : 0.00488619
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.00092
    Left Arm Q1 gauss meter                  : 0.0002432
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000569057
    Left Arm Q2 momentum                     : -1.32155e-06
    Left Arm Q2 gauss meter                  : 0.0011095
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00379251
    Left Arm D1 momentum                     : 0.00252178
    Left Arm D1 NMR                          : 0.218626
    Left Arm Q3 power supply current         : -0.000549185
    Left Arm Q3 momentum                     : -1.37945e-06
    Left Arm Q3 gauss meter                  : -0.00010918
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00148993
    Right Arm Q1 gauss meter                 : -4.81e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.00026991
    Right Arm Q2 momentum                    : -6.27161e-07
    Right Arm Q2 gauss meter                 : 0.0005453
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00339595
    Right Arm D1 momentum                    : 0.00473932
    Right Arm D1 NMR                         : 0.162929
    Right Arm Q3 power supply current        : 7.47261e-06
    Right Arm Q3 momentum                    : 0.0020234
    Right Arm Q3 gauss meter                 : 6.24e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.027042
    Current on Unser monitor                 : 18.2575
    Current on Upstream bcm                  : 0.0400321
    Current on Downstream bcm                : 0.0140519
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00656864
    Tiefenbach Hall A energy                 : 4867.43
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.824677
    MBSY1c Hall A Beam energy                : 4877.58
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 1.21721e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Empty
    Encoder position                         : 3202551
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 25.4246
    pressure fill bottle H2                  : 25.3422
    pressure ballast H2                      : 25.7908
    pressure exhaust H2                      : 25.1789
    cryogen input temp                       : 299.8
    crogen return flow                       : 0
     JT valve setting                        : -0.341797
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1011.log:
    
       Cumulative stats for 5527 events: 
       
       Events failing cut conditions:
       0         Low_beam   5527
       1        Beam_burp      0
       2          Evt_seq      0
       3         Pair_seq   1423
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------