User name apar
Log entry time 16:05:56 on January 5, 2010
Entry number 308964
keyword=End_of_Parity_Run_1016__CODA_Config=Prex
************************************************
Run Number: 1016
End of Run Comment:
Run_type=Production,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=DAQ test,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 1016 at Tue Jan 5 16:05:52 EST 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21805
-----------------------------------------
Wien angle : 0
Wien BDL : 3.18799
Wien field : 60.306
Laser attenuation Hall A : 0
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : -1
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.27
Gun2: PC (PITA) NEG : 6.43
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.72405
Pockels Cell Voltage NEG : 1.73626
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.143584
Photodiode on table : -0.100773
Laser X position on QPD 1 : -110.919
Laser Y position on QPD 1 : -108.937
Laser X position on QPD 2 : 1315.84
Laser Y position on QPD 2 : 442.478
QPD 1 sum : -0.00488319
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : -2335[c]
Position set point for adjustable
mirror 2 (either x or y) : 100[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1418
Polarisation in cavity : LEFT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 2.9024
Calculated polarisation in cavity : 7.58455
Photodiode 1 after Wollaston prism : 0.00682731
Photodiode 2 after Wollaston prism : 0.00519604
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000971633
Left Arm Q1 gauss meter : 0.0002469
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000557826
Left Arm Q2 momentum : -1.29546e-06
Left Arm Q2 gauss meter : 0.0011011
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00375319
Left Arm D1 momentum : 0.00252763
Left Arm D1 NMR : 0.297584
Left Arm Q3 power supply current : -0.000225693
Left Arm Q3 momentum : -5.66898e-07
Left Arm Q3 gauss meter : -0.00012113
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00206787
Right Arm Q1 gauss meter : -5.9e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000129409
Right Arm Q2 momentum : -3.00694e-07
Right Arm Q2 gauss meter : 0.0005364
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00342066
Right Arm D1 momentum : 0.00473087
Right Arm D1 NMR : 0.17398
Right Arm Q3 power supply current : 4.48357e-05
Right Arm Q3 momentum : 0.0020262
Right Arm Q3 gauss meter : 6.2e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0269547
Current on Unser monitor : 18.7128
Current on Upstream bcm : 0.0399437
Current on Downstream bcm : 0.0139656
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00635441
Tiefenbach Hall A energy : 4867.43
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.256356
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 3202551
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.3529
pressure fill bottle H2 : 25.2964
pressure ballast H2 : 25.6962
pressure exhaust H2 : 25.1713
cryogen input temp : 299.8
crogen return flow : 0.445728
JT valve setting : -0.537109
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_1016.log