User name apar
Log entry time 16:34:04 on January 5, 2010
Entry number 308981
keyword=End_of_Parity_Run_1024__CODA_Config=Prex
************************************************
Run Number: 1024
End of Run Comment:
Run_type=Production,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=DAQ test,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 1024 at Tue Jan 5 16:33:55 EST 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21805
-----------------------------------------
Wien angle : 0
Wien BDL : 3.18799
Wien field : 60.306
Laser attenuation Hall A : 0
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : -1
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.27
Gun2: PC (PITA) NEG : 6.43
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.73626
Pockels Cell Voltage NEG : 1.54335
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.144964
Photodiode on table : -0.100773
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : 163.384
Laser X position on QPD 2 : -219.318
Laser Y position on QPD 2 : 7.25044e+06
QPD 1 sum : -0.00366241
QPD 2 sum : 0.00244148
Position set point for adjustable
mirror 1 (either x or y) : -2335[c]
Position set point for adjustable
mirror 2 (either x or y) : 100[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1418
Polarisation in cavity : LEFT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.66
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 4.82512
Calculated polarisation in cavity : 20.1142
Photodiode 1 after Wollaston prism : 0.00709505
Photodiode 2 after Wollaston prism : 0.004624
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00064932
Left Arm Q1 gauss meter : 0.0002774
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.00032571
Left Arm Q2 momentum : -7.56411e-07
Left Arm Q2 gauss meter : 0.0010359
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00388187
Left Arm D1 momentum : 0.00251705
Left Arm D1 NMR : 0.276276
Left Arm Q3 power supply current : -0.000530378
Left Arm Q3 momentum : -1.33221e-06
Left Arm Q3 gauss meter : -0.00012413
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00211559
Right Arm Q1 gauss meter : -5.31e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000118317
Right Arm Q2 momentum : -2.7492e-07
Right Arm Q2 gauss meter : 0.0005488
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00336065
Right Arm D1 momentum : 0.00471725
Right Arm D1 NMR : 0.418211
Right Arm Q3 power supply current : 0.000138243
Right Arm Q3 momentum : 0.00203347
Right Arm Q3 gauss meter : 6.33e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0270389
Current on Unser monitor : 18.5043
Current on Upstream bcm : 0.0400965
Current on Downstream bcm : 0.0139812
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00602664
Tiefenbach Hall A energy : 4867.43
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.800503
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 3202551
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 25.391
pressure fill bottle H2 : 25.3162
pressure ballast H2 : 25.7496
pressure exhaust H2 : 25.1774
cryogen input temp : 299.8
crogen return flow : 0.114286
JT valve setting : -0.390625
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1024.log:
Cumulative stats for 2442 events:
Events failing cut conditions:
0 Low_beam 2442
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 626
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------