NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 12:40:12 on January 20, 2010
Entry number 309036
keyword=End_of_Parity_Run_1046__CODA_Config=Prex
************************************************
Run Number: 1046
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=DAQ test - Installed second ADC18 in LHRS,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1046 at Wed Jan 20 12:40:06 EST 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 0
Wien BDL : 3.18799
Wien field : 0
Laser attenuation Hall A : 0
Laser power Hall A : 0
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : -1
IA Cell Setpoint Hall A : 0
IA Cell Setpoint Hall C : 0
PZT X Setpoint Hall A : 0
PZT Y Setpoint Hall A : 0
PZT X Setpoint Common : 0
PZT Y Setpoint Common : 0
Gun2: PC (PITA) POS : 0
Gun2: PC (PITA) NEG : 0
Gun3: PC (PITA) POS : 0
Gun3: PC (PITA) NEG : 0
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.175865
Photodiode on table : 0.281406
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -108.937
Laser X position on QPD 2 : 146.193
Laser Y position on QPD 2 : -442.532
QPD 1 sum : -0.00366241
QPD 2 sum : 0.00366226
Position set point for adjustable
mirror 1 (either x or y) : 7320[c]
Position set point for adjustable
mirror 2 (either x or y) : 15670[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2713
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0506622
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 0.0384544
Calculated polarisation in cavity : 6.71389
Photodiode 1 after Wollaston prism : 0.00741633
Photodiode 2 after Wollaston prism : 0.00648314
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000854286
Left Arm Q1 gauss meter : 0.000261
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000438024
Left Arm Q2 momentum : -1.01724e-06
Left Arm Q2 gauss meter : 0.0010779
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00361021
Left Arm D1 momentum : 0.00251343
Left Arm D1 NMR : 0.270341
Left Arm Q3 power supply current : -0.000473955
Left Arm Q3 momentum : -1.19049e-06
Left Arm Q3 gauss meter : -0.00012425
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00192471
Right Arm Q1 gauss meter : -5.63e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000262515
Right Arm Q2 momentum : -6.09979e-07
Right Arm Q2 gauss meter : 0.0005305
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00326181
Right Arm D1 momentum : 0.00468618
Right Arm D1 NMR : 0.174671
Right Arm Q3 power supply current : 0.000179343
Right Arm Q3 momentum : 0.0020581
Right Arm Q3 gauss meter : 6.68e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0233175
Current on Unser monitor : 18.5862
Current on Upstream bcm : 0.0331195
Current on Downstream bcm : 0.0135154
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00580732
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : -0
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.8119
pressure fill bottle H2 : 14.5586
pressure ballast H2 : 24.097
pressure exhaust H2 : 14.7402
cryogen input temp : 299.8
crogen return flow : 0.292462
JT valve setting : 98.6328
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_1046.log