User name apar
Log entry time 15:01:03 on January 20, 2010
Entry number 309065
keyword=End_of_Parity_Run_1061__CODA_Config=PrexNoQweak
************************************************
Run Number: 1061
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=DAQ test - Panguin finally working?,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1061 at Wed Jan 20 15:00:54 EST 2010
CODA Configuration: PrexNoQweak
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 0
Wien BDL : 3.18799
Wien field : 0
Laser attenuation Hall A : 0
Laser power Hall A : 0
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : -1
IA Cell Setpoint Hall A : 0
IA Cell Setpoint Hall C : 0
PZT X Setpoint Hall A : 0
PZT Y Setpoint Hall A : 0
PZT X Setpoint Common : 0
PZT Y Setpoint Common : 0
Gun2: PC (PITA) POS : 0
Gun2: PC (PITA) NEG : 0
Gun3: PC (PITA) POS : 0
Gun3: PC (PITA) NEG : 0
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.168784
Photodiode on table : 0.390578
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : 490.171
Laser X position on QPD 2 : 146.193
Laser Y position on QPD 2 : 442.478
QPD 1 sum : -0.00366241
QPD 2 sum : 0.00366226
Position set point for adjustable
mirror 1 (either x or y) : 7320[c]
Position set point for adjustable
mirror 2 (either x or y) : 15670[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2713
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 0.756272
Calculated polarisation in cavity : 6.37385
Photodiode 1 after Wollaston prism : 0.00709505
Photodiode 2 after Wollaston prism : 0.00624479
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000873062
Left Arm Q1 gauss meter : 0.0002441
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000501669
Left Arm Q2 momentum : -1.46935e-06
Left Arm Q2 gauss meter : 0.0010964
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00339574
Left Arm D1 momentum : 0.00253904
Left Arm D1 NMR : 0.270413
Left Arm Q3 power supply current : -0.000361108
Left Arm Q3 momentum : -9.07037e-07
Left Arm Q3 gauss meter : -0.0001288
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00230117
Right Arm Q1 gauss meter : -6.34e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000232936
Right Arm Q2 momentum : -5.41249e-07
Right Arm Q2 gauss meter : 0.0005409
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00349126
Right Arm D1 momentum : 0.00466329
Right Arm D1 NMR : 0.469352
Right Arm Q3 power supply current : 0
Right Arm Q3 momentum : 0.00205362
Right Arm Q3 gauss meter : 6.85e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0233161
Current on Unser monitor : 18.3323
Current on Upstream bcm : 0.0330192
Current on Downstream bcm : 0.013613
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00617484
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : -0
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.789
pressure fill bottle H2 : 14.4823
pressure ballast H2 : 24.1764
pressure exhaust H2 : 14.7112
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.0957
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1061.log:
Cumulative stats for 6839 events:
Events failing cut conditions:
0 Low_beam 6839
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
Ending the online analysis