User name apar
Log entry time 12:35:16 on February 8, 2010
Entry number 309177
keyword=End_of_Parity_Run_1115__CODA_Config=Prex
************************************************
Run Number: 1115
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 240Hz - Long Run with healthy LED-PMT signals. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1115 at Mon Feb 8 12:35:08 EST 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 0
Wien BDL : 3.18799
Wien field : 60.306
Laser attenuation Hall A : 0
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : -1
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.27
Gun2: PC (PITA) NEG : 6.43
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : 240 Hz Line Sync
Helicity Delay Set : 8 windows
Helicity Pattern Set : Octet
Helicity Clock Read : 240 Hz Line Sync
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Octet
Helicity Frequency : 240
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 26mW
Calculated power in cavity : 0.186247
Photodiode on table : 0.45339
Laser X position on QPD 1 : -110.919
Laser Y position on QPD 1 : -163.404
Laser X position on QPD 2 : 438.596
Laser Y position on QPD 2 : 442.478
QPD 1 sum : -0.00488319
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : -5665[c]
Position set point for adjustable
mirror 2 (either x or y) : 420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2713
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -7.95276
Calculated polarisation in cavity : 16.7715
Photodiode 1 after Wollaston prism : 0.00859438
Photodiode 2 after Wollaston prism : 0.00612561
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00115626
Left Arm Q1 gauss meter : 0.0002323
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000565313
Left Arm Q2 momentum : -1.0781e-06
Left Arm Q2 gauss meter : 0.0011254
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00387472
Left Arm D1 momentum : 0.00254544
Left Arm D1 NMR : 0.270056
Left Arm Q3 power supply current : -0.000443862
Left Arm Q3 momentum : -1.07711e-06
Left Arm Q3 gauss meter : -0.00011155
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000705196
Right Arm Q1 gauss meter : -3.33e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000244028
Right Arm Q2 momentum : -3.35059e-07
Right Arm Q2 gauss meter : 0.0005356
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00324769
Right Arm D1 momentum : 0.00466438
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -6.35172e-05
Right Arm Q3 momentum : 0.00188291
Right Arm Q3 gauss meter : 3.66e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0228624
Current on Unser monitor : 18.6887
Current on Upstream bcm : 0.0333802
Current on Downstream bcm : 0.0123446
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00166351
Tiefenbach Hall A energy : 4867.43
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 4.38768
MBSY1c Hall A Beam energy : 4877.58
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 1.21721e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.9432
pressure fill bottle H2 : 14.8943
pressure ballast H2 : 25.3895
pressure exhaust H2 : 14.7692
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 97.998
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1115.log:
Cumulative stats for 82085 events:
Events failing cut conditions:
0 Low_beam 54035
1 Beam_burp 1
2 Evt_seq 313
3 Pair_seq 822
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------