User name apar
Log entry time 17:11:21 on February 10, 2010
Entry number 309204
keyword=End_of_Parity_Run_1131__CODA_Config=PrexNoQweak
************************************************
Run Number: 1131
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=0,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1131 at Wed Feb 10 17:11:12 EST 2010
CODA Configuration: PrexNoQweak
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 91.2084
Wien BDL : 2368.98
Wien field : 60.469
Laser attenuation Hall A : 60
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : -1
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.958
Gun2: PC (PITA) NEG : 5.725
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 0.0512821
Pockels Cell Voltage NEG : 0
Helicity Clock Set : 240 Hz Line Sync
Helicity Delay Set : 8 windows
Helicity Pattern Set : Octet
Helicity Clock Read : 240 Hz Line Sync
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Octet
Helicity Frequency : 240
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr603mW
Calculated power in cavity : 0.179955
Photodiode on table : 0.445165
Laser X position on QPD 1 : 443.602
Laser Y position on QPD 1 : -326.797
Laser X position on QPD 2 : -7.18596e+06
Laser Y position on QPD 2 : -221.259
QPD 1 sum : -0.00366241
QPD 2 sum : -7.45058e-08
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2713
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 4.82146
Calculated polarisation in cavity : 18.2188
Photodiode 1 after Wollaston prism : 0.00840696
Photodiode 2 after Wollaston prism : 0.00581575
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000668096
Left Arm Q1 gauss meter : 0.0002665
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.0005129
Left Arm Q2 momentum : -1.19113e-06
Left Arm Q2 gauss meter : 0.001061
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00379965
Left Arm D1 momentum : 0.00248337
Left Arm D1 NMR : 0.270094
Left Arm Q3 power supply current : -0.000500285
Left Arm Q3 momentum : -1.25662e-06
Left Arm Q3 gauss meter : -0.00011392
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00231707
Right Arm Q1 gauss meter : -5.21e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.00026991
Right Arm Q2 momentum : -5.67023e-07
Right Arm Q2 gauss meter : 0.0005408
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00316649
Right Arm D1 momentum : 0.00464312
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -5.97809e-05
Right Arm Q3 momentum : -1.50238e-07
Right Arm Q3 gauss meter : 3.69e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0227811
Current on Unser monitor : 17.4966
Current on Upstream bcm : 0.0331489
Current on Downstream bcm : 0.0124134
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.002407
Tiefenbach Hall A energy : 21.1615
Tiefenbach Hall C energy : 20.6623
Delta(E)/E width (MV_AI_DXWID) : 4.37721
MBSY1c Hall A Beam energy : 21.1371
MBSY3c Hall C Beam energy : 21.1371
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 5274.8
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.6365
pressure fill bottle H2 : 14.435
pressure ballast H2 : 24.8798
pressure exhaust H2 : 14.4182
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.291
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1131.log:
Cumulative stats for 195046 events:
Events failing cut conditions:
0 Low_beam 120395
1 Beam_burp 0
2 Evt_seq 739
3 Pair_seq 1826
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------