NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 14:13:10 on February 13, 2010
Entry number 309246
keyword=End_of_Parity_Run_1120__CODA_Config=Prex
keyword=End_of_Parity_Run_1119__CODA_Config=Prex
************************************************
Run Number: 1120
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 240Hz - Long Run with healthy LED-PMT signal on RHRS. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1120 at Sat Feb 13 14:13:02 EST 2010
CODA Configuration: Prex
Compton Run Number : 21965
-----------------------------------------
Wien angle : 0
Wien BDL : 0
Wien field : 0
Laser attenuation Hall A : 150
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 0
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.958
Gun2: PC (PITA) NEG : 5.725
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : 240 Hz Line Sync
Helicity Delay Set : 8 windows
Helicity Pattern Set : Octet
Helicity Clock Read : 240 Hz Line Sync
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Octet
Helicity Frequency : 240
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr296mW
Calculated power in cavity : 0.178678
Photodiode on table : -0.12176
Laser X position on QPD 1 : -443.656
Laser Y position on QPD 1 : -326.797
Laser X position on QPD 2 : -438.65
Laser Y position on QPD 2 : -442.532
QPD 1 sum : -0.00244163
QPD 2 sum : -0.00122085
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2713
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0506622
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : -22.0161
Fast locking signal sent to laser : -22.1846
Calculated polarisation in cavity : 15.2716
Photodiode 1 after Wollaston prism : 0.00813922
Photodiode 2 after Wollaston prism : 0.0059826
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.640879
Left Arm Q1 momentum : 0.00166789
Left Arm Q1 gauss meter : 0.0002127
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000385611
Left Arm Q2 momentum : -1.20852e-06
Left Arm Q2 gauss meter : 0.0010475
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00345651
Left Arm D1 momentum : 0.00253431
Left Arm D1 NMR : 0.270382
Left Arm Q3 power supply current : -0.000410008
Left Arm Q3 momentum : -1.02986e-06
Left Arm Q3 gauss meter : -0.00013046
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.0026193
Right Arm Q1 gauss meter : -6.94e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -6.65531e-05
Right Arm Q2 momentum : -1.54643e-07
Right Arm Q2 gauss meter : 0.0005337
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00349126
Right Arm D1 momentum : 0.00465893
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 0.000149452
Right Arm Q3 momentum : 0.00191985
Right Arm Q3 gauss meter : 4.27e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0236952
Current on Unser monitor : 18.7081
Current on Upstream bcm : 0.0348722
Current on Downstream bcm : 0.0126307
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00264652
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 300
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5418
pressure fill bottle H2 : 14.464
pressure ballast H2 : 24.4755
pressure exhaust H2 : 14.551
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.4375
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1120.log:
Cumulative stats for 210594 events:
Events failing cut conditions:
0 Low_beam 138594
1 Beam_burp 0
2 Evt_seq 794
3 Pair_seq 2480
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------
************************************************
Run Number: 1119
End of Run Comment:
Run_type=Test,beam_energy=4.87,beam_polarization=87,beam_raster=on,comment_text=PMT test - 240Hz - Long Run with healthy LED-PMT signal on RHRS. HV=1200,dithering_magnet=on,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=60 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1119 at Sat Feb 13 14:13:03 EST 2010
CODA Configuration: Prex
Compton Run Number : 21965
-----------------------------------------
Wien angle : 0
Wien BDL : 0
Wien field : 0
Laser attenuation Hall A : 150
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 0
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.958
Gun2: PC (PITA) NEG : 5.725
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 0
Pockels Cell Voltage NEG : 0
Helicity Clock Set : 240 Hz Line Sync
Helicity Delay Set : 8 windows
Helicity Pattern Set : Octet
Helicity Clock Read : 240 Hz Line Sync
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Octet
Helicity Frequency : 240
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr296mW
Calculated power in cavity : 0.178678
Photodiode on table : -0.117572
Laser X position on QPD 1 : -221.835
Laser Y position on QPD 1 : -326.797
Laser X position on QPD 2 : -438.543
Laser Y position on QPD 2 : -442.532
QPD 1 sum : -7.45058e-08
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2713
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0506622
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : -22.0161
Fast locking signal sent to laser : -22.1846
Calculated polarisation in cavity : 11.5837
Photodiode 1 after Wollaston prism : 0.0075502
Photodiode 2 after Wollaston prism : 0.0059826
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.694286
Left Arm Q1 momentum : 0.00150674
Left Arm Q1 gauss meter : 0.0002127
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000430537
Left Arm Q2 momentum : -8.95521e-07
Left Arm Q2 gauss meter : 0.0010475
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00345651
Left Arm D1 momentum : 0.00255352
Left Arm D1 NMR : 0.270382
Left Arm Q3 power supply current : -0.00046267
Left Arm Q3 momentum : -1.02986e-06
Left Arm Q3 gauss meter : -0.00013046
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.0026193
Right Arm Q1 gauss meter : -5.9e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -5.54609e-05
Right Arm Q2 momentum : -1.54643e-07
Right Arm Q2 gauss meter : 0.0005337
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00363247
Right Arm D1 momentum : 0.00465893
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -2.98904e-05
Right Arm Q3 momentum : 0.00191985
Right Arm Q3 gauss meter : 4.27e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0237514
Current on Unser monitor : 18.7081
Current on Upstream bcm : 0.0348722
Current on Downstream bcm : 0.0126307
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00264652
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 300
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5418
pressure fill bottle H2 : 14.464
pressure ballast H2 : 24.4755
pressure exhaust H2 : 14.551
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.4375
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1119.log:
Cumulative stats for 100579 events:
Events failing cut conditions:
0 Low_beam 65879
1 Beam_burp 0
2 Evt_seq 377
3 Pair_seq 1197
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------