NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 13:27:53 on February 18, 2010
Entry number 309355
keyword=End_of_Parity_Run_1188__CODA_Config=NoRight
************************************************
Run Number: 1188
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=new ADCX in Left Arm,dithering_magnet=off,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1188 at Thu Feb 18 13:27:44 EST 2010
CODA Configuration: NoRight
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22012
-----------------------------------------
Wien angle : 0
Wien BDL : 10
Wien field : 0.005
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 0
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.881
Gun2: PC (PITA) NEG : 5.802
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.84371
Pockels Cell Voltage NEG : 1.69231
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.172089
Photodiode on table : -0.0713858
Laser X position on QPD 1 : -443.656
Laser Y position on QPD 1 : 980.312
Laser X position on QPD 2 : -438.65
Laser Y position on QPD 2 : -442.532
QPD 1 sum : -0.00366241
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2613
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0506622
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : -21.8843
Fast locking signal sent to laser : -22.2359
Calculated polarisation in cavity : 16.8514
Photodiode 1 after Wollaston prism : 0.00773762
Photodiode 2 after Wollaston prism : 0.0055059
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.694286
Left Arm Q1 momentum : 0.00200898
Left Arm Q1 gauss meter : 0.0001779
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000497925
Left Arm Q2 momentum : -1.15635e-06
Left Arm Q2 gauss meter : 0.0011316
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00327778
Left Arm D1 momentum : 0.00248726
Left Arm D1 NMR : 0.270391
Left Arm Q3 power supply current : -0.000741024
Left Arm Q3 momentum : -1.86131e-06
Left Arm Q3 gauss meter : -0.00012854
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.00270944
Right Arm Q1 gauss meter : -7.69e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000314278
Right Arm Q2 momentum : -7.30256e-07
Right Arm Q2 gauss meter : 0.0005319
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00360776
Right Arm D1 momentum : 0.00461505
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : 0.000115825
Right Arm Q3 momentum : 0.00194
Right Arm Q3 gauss meter : 4.66e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0270989
Current on Unser monitor : 18.1851
Current on Upstream bcm : 0.0409268
Current on Downstream bcm : 0.0132709
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00210003
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 5059.73
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 5075.41
MBSY1c magnet current (amp) : 300
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5205
pressure fill bottle H2 : 14.461
pressure ballast H2 : 24.6967
pressure exhaust H2 : 14.5403
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.0469
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1188.log:
Cumulative stats for 20561 events:
Events failing cut conditions:
0 Low_beam 0
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 1
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------