User name apar
Log entry time 18:58:42 on February 20, 2010
Entry number 309455
keyword=End_of_Parity_Run_1217__CODA_Config=Prex
************************************************
Run Number: 1217
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=bpm pedestals,dithering_magnet=off,dithering_magnets=,leftarm_p=3660,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=3100,rightarm_theta=12.9,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1217 at Sat Feb 20 18:58:34 EST 2010
CODA Configuration: Prex
Compton Run Number : 22012
-----------------------------------------
Wien angle : 0
Wien BDL : 6
Wien field : 0
Laser attenuation Hall A : 122
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 0
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.958
Gun2: PC (PITA) NEG : 5.725
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.97192
Pockels Cell Voltage NEG : 2.75458
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.149487
Photodiode on table : -0.0839731
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : 163.384
Laser X position on QPD 2 : 146.193
Laser Y position on QPD 2 : -442.424
QPD 1 sum : -0.00366241
QPD 2 sum : 0.00366226
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2613
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : -22.0344
Fast locking signal sent to laser : -22.3238
Calculated polarisation in cavity : 16.4794
Photodiode 1 after Wollaston prism : 0.00688086
Photodiode 2 after Wollaston prism : 0.00507687
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.694286
Left Arm Q1 momentum : 0.00163973
Left Arm Q1 gauss meter : 0.0002042
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000539107
Left Arm Q2 momentum : -8.14163e-07
Left Arm Q2 gauss meter : 0.0010441
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00328493
Left Arm D1 momentum : 0.0025421
Left Arm D1 NMR : 0.270439
Left Arm Q3 power supply current : -0.000425054
Left Arm Q3 momentum : -1.53929e-06
Left Arm Q3 gauss meter : -0.00012051
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.00106575
Right Arm Q1 gauss meter : -4.01e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000221844
Right Arm Q2 momentum : -5.88547e-07
Right Arm Q2 gauss meter : 0.0005242
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00353009
Right Arm D1 momentum : 0.00466928
Right Arm D1 NMR : 6.85974
Right Arm Q3 power supply current : 0.000112089
Right Arm Q3 momentum : 0.00193776
Right Arm Q3 gauss meter : 4.59e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0232318
Current on Unser monitor : 17.6917
Current on Upstream bcm : 0.0338954
Current on Downstream bcm : 0.0125682
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.0031672
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 5059.73
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 5075.41
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.6929
pressure fill bottle H2 : 14.583
pressure ballast H2 : 24.3732
pressure exhaust H2 : 14.7341
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.4863
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_1217.log