    User name apar

    Log entry time 17:44:02 on February 21, 2010

    Entry number 309549

    keyword=End_of_Parity_Run_1258__CODA_Config=Prex
    ************************************************
     Run Number: 1258
     End of Run Comment:
    
    Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=injector studies::PITA scan, RHWP 300, 30 Hz, IHWP OUT,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1258 at Sun Feb 21 17:43:54 EST 2010
    CODA Configuration: Prex
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 22012
    -----------------------------------------
    Wien angle                               : 0
    Wien BDL                                 : 6
    Wien field                               : 0
    Laser attenuation Hall A                 : 132
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 300
    IA Cell Setpoint  Hall A                 : 5
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 5.958
    Gun2: PC (PITA) NEG                      : 5.725
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.61538
    Pockels Cell Voltage NEG                 : 2.39316
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Pair
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Pair
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 31mW
    Calculated power in cavity               : 0.196071
    Photodiode on table                      : -0.0839731
    Laser X position on QPD 1                : -147.891
    Laser Y position on QPD 1                : 245.089
    Laser X position on QPD 2                : 438.596
    Laser Y position on QPD 2                : 442.478
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : -0.00122085
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 5320[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 8520[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2613
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0506622
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : -22.0418
    Fast locking signal sent to laser        : -22.3238
    Calculated polarisation in cavity        : 20.9416
    Photodiode 1 after Wollaston prism       : 0.00886212
    Photodiode 2 after Wollaston prism       : 0.00612561
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.694286
    Left Arm Q1 momentum                     : 0.00190415
    Left Arm Q1 gauss meter                  : 0.0001955
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000452999
    Left Arm Q2 momentum                     : -1.06597e-06
    Left Arm Q2 gauss meter                  : 0.0010557
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00337072
    Left Arm D1 momentum                     : 0.00246305
    Left Arm D1 NMR                          : 0.270365
    Left Arm Q3 power supply current         : -0.000383677
    Left Arm Q3 momentum                     : -7.65891e-07
    Left Arm Q3 gauss meter                  : -0.00013052
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0.16022
    Right Arm Q1 momentum                    : 0.00303818
    Right Arm Q1 gauss meter                 : -6.54e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000362345
    Right Arm Q2 momentum                    : -8.12361e-07
    Right Arm Q2 gauss meter                 : 0.0005281
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00373484
    Right Arm D1 momentum                    : 0.00463685
    Right Arm D1 NMR                         : 6.85794
    Right Arm Q3 power supply current        : 0
    Right Arm Q3 momentum                    : 0.00193104
    Right Arm Q3 gauss meter                 : 4.5e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0231359
    Current on Unser monitor                 : 18.9932
    Current on Upstream bcm                  : 0.0338774
    Current on Downstream bcm                : 0.0124192
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00298418
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 5059.73
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 7172.88
    MBSY3c Hall C Beam energy                : 5075.41
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 1.79e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0
    Raster Y width                                : 0
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.7082
    pressure fill bottle H2                  : 14.6273
    pressure ballast H2                      : 24.6159
    pressure exhaust H2                      : 14.7189
    cryogen input temp                       : 299.8
    crogen return flow                       : 0
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 0
    No HAPPEX feedback runlog entry for Run #1258
      Was feedback on?