Log entry time 18:38:25 on February 21, 2010
Entry number 309560
keyword=End_of_Parity_Run_1263__CODA_Config=Prex
************************************************
Run Number: 1263
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=injector studies::RHWP 150, 30 Hz, IHWP OUT, New PC voltages,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1263 at Sun Feb 21 18:38:18 EST 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22012
-----------------------------------------
Wien angle : 0
Wien BDL : 6
Wien field : 0
Laser attenuation Hall A : 132
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 150
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.489
Gun2: PC (PITA) NEG : 5.194
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.82051
Pockels Cell Voltage NEG : 2.61538
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Pair
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Pair
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.195554
Photodiode on table : -0.062986
Laser X position on QPD 1 : -110.919
Laser Y position on QPD 1 : 65.3547
Laser X position on QPD 2 : -438.543
Laser Y position on QPD 2 : -221.219
QPD 1 sum : -0.00488319
QPD 2 sum : -0.00122085
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2613
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0494415
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : -22.0381
Fast locking signal sent to laser : -22.3274
Calculated polarisation in cavity : 11.8056
Photodiode 1 after Wollaston prism : 0.00846051
Photodiode 2 after Wollaston prism : 0.00667382
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.694286
Left Arm Q1 momentum : 0.00164442
Left Arm Q1 gauss meter : 0.0002114
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000662652
Left Arm Q2 momentum : -1.48564e-06
Left Arm Q2 gauss meter : 0.0010631
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00330995
Left Arm D1 momentum : 0.0025524
Left Arm D1 NMR : 0.270392
Left Arm Q3 power supply current : -0.000252023
Left Arm Q3 momentum : -5.03085e-07
Left Arm Q3 gauss meter : -0.00011751
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.106813
Right Arm Q1 momentum : 0.00200954
Right Arm Q1 gauss meter : -5.79e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000110922
Right Arm Q2 momentum : -9.94728e-08
Right Arm Q2 gauss meter : 0.0005283
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00353715
Right Arm D1 momentum : 0.00465974
Right Arm D1 NMR : 6.859
Right Arm Q3 power supply current : -7.84624e-05
Right Arm Q3 momentum : -2.38667e-07
Right Arm Q3 gauss meter : 4.56e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0234016
Current on Unser monitor : 18.0189
Current on Upstream bcm : 0.0343059
Current on Downstream bcm : 0.0124973
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00369637
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 5059.73
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 5075.41
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.7265
pressure fill bottle H2 : 14.6212
pressure ballast H2 : 24.5212
pressure exhaust H2 : 14.6548
cryogen input temp : 299.8
crogen return flow : 1.59751
JT valve setting : 97.9492
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #1263
Was feedback on?