User name apar
Log entry time 17:02:46 on February 22, 2010
Entry number 309635
keyword=Start_Parity_Run_1291__CODA_Config=CHInj2_Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=injector studies:: 240Hz, 50uA, PITA scan!,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 1291 at Mon Feb 22 17:01:35 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22012
-----------------------------------------
Wien angle : 0
Wien BDL : -9.7
Wien field : 0
Laser attenuation Hall A : 134
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 5
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.958
Gun2: PC (PITA) NEG : 5.725
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.82051
Pockels Cell Voltage NEG : 2.59341
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 31mW
Calculated power in cavity : 0.185619
Photodiode on table : -0.0545862
Laser X position on QPD 1 : -221.835
Laser Y position on QPD 1 : -108.937
Laser X position on QPD 2 : -438.543
Laser Y position on QPD 2 : 7.25044e+06
QPD 1 sum : -0.00244163
QPD 2 sum : -0.00122085
Position set point for adjustable
mirror 1 (either x or y) : 5320[c]
Position set point for adjustable
mirror 2 (either x or y) : 8520[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2613
Polarisation in cavity : RIGHT
Reflection photodiode : 0.00549346
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.0201427
Fast locking signal sent to laser : 0.00915572
Calculated polarisation in cavity : 9.46424
Photodiode 1 after Wollaston prism : 0.00800535
Photodiode 2 after Wollaston prism : 0.00655464
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
Left S1 HV
S1 Slot1 ch0 : -5.5
S1 Slot1 ch1 : -5.4
S1 Slot1 ch2 : -5.9
S1 Slot1 ch3 : -4.7
S1 Slot1 ch4 : -5
S1 Slot1 ch5 : -4.6
S1 Slot1 ch6 : -5
S1 Slot1 ch7 : -5.8
S1 Slot1 ch8 : -7.3
S1 Slot1 ch9 : -6.6
S1 Slot1 ch10 : -5.8
S1 Slot1 ch11 : -6.7
-----
Left S2 HV Left PMTs
S2 Slot0 ch0 Left : -1639.8
S2 Slot0 ch1 Left : -1690.8
S2 Slot0 ch2 Left : -2015.9
S2 Slot0 ch3 Left : -1820.2
S2 Slot0 ch4 Left : -1859.2
S2 Slot0 ch5 Left : -1661.7
S2 Slot0 ch6 Left : -1837.5
S2 Slot0 ch7 Left : -1803.6
S2 Slot0 ch8 Left : -1796.6
S2 Slot0 ch9 Left : -1918.4
S2 Slot0 ch10 Left : -1976.3
S2 Slot0 ch11 Left : -1823.7
S2 Slot13 ch0 Left : -1954.5
S2 Slot13 ch1 Left : -2006.7
S2 Slot13 ch2 Left : -1776.6
S2 Slot13 ch3 Left : -1559.8
-----
Left S2 HV Right PMTs
S2 Slot12 ch0 Right : -1483.5
S2 Slot12 ch1 Right : -1626.8
S2 Slot12 ch2 Right : -1780.8
S2 Slot12 ch3 Right : -1699.9
S2 Slot12 ch4 Right : -1757.2
S2 Slot12 ch5 Right : -1732.5
S2 Slot12 ch6 Right : -1765.9
S2 Slot12 ch7 Right : -1472.1
S2 Slot12 ch8 Right : -1825.3
S2 Slot12 ch9 Right : -1700.7
S2 Slot12 ch10 Right : -1830
S2 Slot12 ch11 Right : -1550.9
S2 Slot13 ch4 Right : -1553
S2 Slot13 ch5 Right : -1635.9
S2 Slot13 ch6 Right : -1650
S2 Slot13 ch7 Right : -1626.6
-----
Left Cerenkov HV
GCER Slot2 ch0 : -1522.3
GCER Slot2 ch1 : -1437.2
GCER Slot2 ch2 : -1511.2
GCER Slot2 ch3 : -1421.2
GCER Slot2 ch4 : -1766.4
GCER Slot2 ch5 : -1990.5
GCER Slot2 ch6 : -20.9
GCER Slot2 ch7 : -1724.8
GCER Slot2 ch8 : -1960.8
GCER Slot2 ch9 : -1520.5
GCER Slot2 ch10 : -1745.2
GCER Slot2 ch11 : -1500.9
-----
Left Pion Rejector Layer 1 HV
PRL1 Slot3 ch0 : -12.8
PRL1 Slot3 ch1 : -12.5
PRL1 Slot3 ch2 : -14.2
PRL1 Slot3 ch3 : -13.4
PRL1 Slot3 ch4 : -12.6
PRL1 Slot3 ch5 : -13.9
PRL1 Slot3 ch6 : -12.7
PRL1 Slot3 ch7 : -15.5
PRL1 Slot3 ch8 : -13.4
PRL1 Slot3 ch9 : -13.9
PRL1 Slot3 ch10 : -13.7
PRL1 Slot3 ch11 : -12.1
PRL1 Slot4 ch0 : -14.7
PRL1 Slot4 ch1 : -13.2
PRL1 Slot4 ch2 : -15.6
PRL1 Slot4 ch3 : -12.7
PRL1 Slot4 ch4 : -13
PRL1 Slot4 ch5 : -15.5
PRL1 Slot4 ch6 : -13.8
PRL1 Slot4 ch7 : -12.8
PRL1 Slot4 ch8 : -14.5
PRL1 Slot4 ch9 : -15.2
PRL1 Slot4 ch10 : -19.4
PRL1 Slot4 ch11 : -15.9
PRL1 Slot5 ch0 : -23.1
PRL1 Slot5 ch1 : -23.8
PRL1 Slot5 ch2 : -24
PRL1 Slot5 ch3 : -23.8
PRL1 Slot5 ch4 : -22.9
PRL1 Slot5 ch5 : -20.4
PRL1 Slot5 ch6 : -24.5
PRL1 Slot5 ch7 : -25.7
PRL1 Slot5 ch8 : -24.6
PRL1 Slot5 ch9 : -23.7
PRL1 Slot5 ch10 : -27.3
PRL1 Slot5 ch11 : -27.2
-----
Left Pion Rejector Layer 2 HV
PRL2 Slot9 ch0 : -20
PRL2 Slot9 ch1 : -24.6
PRL2 Slot9 ch2 : -20.3
PRL2 Slot9 ch3 : -22.7
PRL2 Slot9 ch4 : -21.5
PRL2 Slot9 ch5 : -21.7
PRL2 Slot9 ch6 : -23.5
PRL2 Slot9 ch7 : -22
PRL2 Slot9 ch8 : -18.9
PRL2 Slot9 ch9 : -22.9
PRL2 Slot9 ch10 : -22.5
PRL2 Slot9 ch11 : -20
PRL2 Slot10 ch0 : -13.4
PRL2 Slot10 ch1 : -15.5
PRL2 Slot10 ch2 : -16.8
PRL2 Slot10 ch3 : -18.5
PRL2 Slot10 ch4 : -15.4
PRL2 Slot10 ch5 : -14.9
PRL2 Slot10 ch6 : -18
PRL2 Slot10 ch7 : -17.8
PRL2 Slot10 ch8 : -14.4
PRL2 Slot10 ch9 : -19.8
PRL2 Slot10 ch10 : -15.8
PRL2 Slot10 ch11 : -16.5
PRL2 Slot11 ch0 : -19.3
PRL2 Slot11 ch1 : -19.2
PRL2 Slot11 ch2 : -18.9
PRL2 Slot11 ch3 : -20
PRL2 Slot11 ch4 : -16
PRL2 Slot11 ch5 : -19.6
PRL2 Slot11 ch6 : -21.2
PRL2 Slot11 ch7 : -18.3
PRL2 Slot11 ch8 : -20.7
PRL2 Slot11 ch9 : -20.7
PRL2 Slot11 ch10 : -24.4
PRL2 Slot11 ch11 : -25.5
-----
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.640879
Left Arm Q1 momentum : 0.0018932
Left Arm Q1 gauss meter : 0.0001786
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000464231
Left Arm Q2 momentum : -9.40065e-07
Left Arm Q2 gauss meter : 0.0011141
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00324919
Left Arm D1 momentum : 0.00252095
Left Arm D1 NMR : 0.270398
Left Arm Q3 power supply current : -0.000169269
Left Arm Q3 momentum : -3.37893e-07
Left Arm Q3 gauss meter : -0.00013563
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.106813
Right Arm Q1 momentum : 0.00183987
Right Arm Q1 gauss meter : -4.19e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000528727
Right Arm Q2 momentum : -1.18538e-06
Right Arm Q2 gauss meter : 0.0005386
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00349479
Right Arm D1 momentum : 0.00465974
Right Arm D1 NMR : 6.8587
Right Arm Q3 power supply current : 0.000291432
Right Arm Q3 momentum : 0.00192097
Right Arm Q3 gauss meter : 4.4e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.5625
Left Arm Bottom VDC Current : 1.61133
Right Arm Top VDC Current : -1.61133
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0200195
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00878906
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0218959
Current on Unser monitor : 17.894
Current on Upstream bcm : 0.0315139
Current on Downstream bcm : 0.0124145
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00256345
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 5059.73
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 5075.41
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00102539
HacL_HPE1313A:0_Ch58 : -0.258789
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.0571289
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.000488281
HacR_HPE1313A:0_Ch58 : -0.643066
HacR_HPE1313A:0_Ch55 : 21.7773
HacR_HPE1313A:0_Ch54 : -1.02441
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.4656
pressure fill bottle H2 : 14.4091
pressure ballast H2 : 24.3992
pressure exhaust H2 : 14.5892
cryogen input temp : 299.8
crogen return flow : 0.947832
JT valve setting : 98.584
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
anatype fdbk
curmon bcm1
feedback IA off 2 bcm1
feedback PITA on 1 bcm1
feedback PZT off 20 bpm4b
IAHallCparam slope 200.0
IAparam slope -1.0
PITAparam slope -28790
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Low_beam_c
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 1 1200