    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 15:56:41 on February 24, 2010

    Entry number 309858

    keyword=End_of_Parity_Run_1378__CODA_Config=CHInj2
    ************************************************
     Run Number: 1378
     End of Run Comment:
    
    Run_type=Parityscan,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=pitch scan, HWP out,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1378 at Wed Feb 24 15:56:36 EST 2010
    CODA Configuration: CHInj2
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 22025
    -----------------------------------------
    Wien angle                               : 0
    Wien BDL                                 : 2098.1
    Wien field                               : 54.162
    Laser attenuation Hall A                 : 92
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 150
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 5.225
    Gun2: PC (PITA) NEG                      : 6.458
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Pair
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Pair
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 0.219263
    Photodiode on table                      : 0
    Laser X position on QPD 1                : -147.891
    Laser Y position on QPD 1                : -108.937
    Laser X position on QPD 2                : -219.278
    Laser Y position on QPD 2                : 221.246
    QPD 1 sum                                : -0.00244163
    QPD 2 sum                                : -0.00122085
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -6165[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 59020[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.00549346
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.0128181
    Fast locking signal sent to laser        : 0.00549339
    Calculated polarisation in cavity        : 2.89615
    Photodiode 1 after Wollaston prism       : 0.00891566
    Photodiode 2 after Wollaston prism       : 0.00841378
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.0534066
    Left Arm Q1 momentum                     : 0.000829252
    Left Arm Q1 gauss meter                  : 0.000256
    Left Arm Q1 power supply polarity        : 0
    Left Arm Q2 power supply current         : -0.000213396
    Left Arm Q2 momentum                     : -4.78426e-07
    Left Arm Q2 gauss meter                  : 0.0010862
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00201957
    Left Arm D1 momentum                     : 0.00248921
    Left Arm D1 NMR                          : 0.270374
    Left Arm Q3 power supply current         : -0.000741024
    Left Arm Q3 momentum                     : -1.47922e-06
    Left Arm Q3 gauss meter                  : -0.00012239
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0.16022
    Right Arm Q1 momentum                    : 0.00191941
    Right Arm Q1 gauss meter                 : -5.62e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000713597
    Right Arm Q2 momentum                    : -1.37604e-06
    Right Arm Q2 gauss meter                 : 0.0005295
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00347008
    Right Arm D1 momentum                    : 0.00465538
    Right Arm D1 NMR                         : 6.8582
    Right Arm Q3 power supply current        : 0.000265278
    Right Arm Q3 momentum                    : 0.00191537
    Right Arm Q3 gauss meter                 : 4.22e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0227426
    Current on Unser monitor                 : 18.8787
    Current on Upstream bcm                  : 0.0334935
    Current on Downstream bcm                : 0.0119918
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00176431
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 15616
    MBSY3c Hall C Beam energy                : 8874.29
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 3.897e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0
    Raster Y width                                : 0
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.5251
    pressure fill bottle H2                  : 14.6059
    pressure ballast H2                      : 24.3778
    pressure exhaust H2                      : 14.6136
    cryogen input temp                       : 299.8
    crogen return flow                       : 1.043
     JT valve setting                        : 98.2422
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
     Did not obtain HAPPEX feedback cumulative results from 
        /adaqfs/halla/apar/feedback/runlog/ffb_1378.log