• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 16:31:14 on February 25, 2010

    Entry number 309965

    keyword=End_of_Parity_Run_1427__CODA_Config=CHInj2
    ************************************************
     Run Number: 1427
     End of Run Comment:
    
    Run_type=Parityscan,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=injector studies::analyzer out, RHWP scan, IHWP IN, PITA offset = 240V,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1427 at Thu Feb 25 16:31:07 EST 2010
    CODA Configuration: CHInj2
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : 0
    Wien BDL                                 : 2098.1
    Wien field                               : 54.162
    Laser attenuation Hall A                 : 90
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 50
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 2.105
    Gun2: PC (PITA) NEG                      : 9.578
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0.043956
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Pair
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Pair
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 1.33301
    Photodiode on table                      : -0.0335992
    Laser X position on QPD 1                : -55.4599
    Laser Y position on QPD 1                : -36.3128
    Laser X position on QPD 2                : 438.596
    Laser Y position on QPD 2                : 442.478
    QPD 1 sum                                : -0.0097663
    QPD 2 sum                                : 0.0012207
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -6165[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 59020[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.00549346
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.0164804
    Fast locking signal sent to laser        : 0.00915572
    Calculated polarisation in cavity        : 15.5714
    Photodiode 1 after Wollaston prism       : 0.0613387
    Photodiode 2 after Wollaston prism       : 0.0448099
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.0534066
    Left Arm Q1 momentum                     : 0.000869932
    Left Arm Q1 gauss meter                  : 0.0002534
    Left Arm Q1 power supply polarity        : 0
    Left Arm Q2 power supply current         : -0.000662652
    Left Arm Q2 momentum                     : -1.38492e-06
    Left Arm Q2 gauss meter                  : 0.0010875
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00213395
    Left Arm D1 momentum                     : 0.00248587
    Left Arm D1 NMR                          : 0.270407
    Left Arm Q3 power supply current         : -0.000522855
    Left Arm Q3 momentum                     : -1.0287e-06
    Left Arm Q3 gauss meter                  : -0.00013422
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00242842
    Right Arm Q1 gauss meter                 : -6.74e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000232936
    Right Arm Q2 momentum                    : -5.80258e-08
    Right Arm Q2 gauss meter                 : 0.0005345
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00335006
    Right Arm D1 momentum                    : 0.00464121
    Right Arm D1 NMR                         : 6.85932
    Right Arm Q3 power supply current        : 9.34076e-05
    Right Arm Q3 momentum                    : 0.00191985
    Right Arm Q3 gauss meter                 : 4.3e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0229181
    Current on Unser monitor                 : 19.0845
    Current on Upstream bcm                  : 0.0336995
    Current on Downstream bcm                : 0.0121367
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.0018127
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 24271.1
    MBSY3c Hall C Beam energy                : 8874.29
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 6.05688e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0
    Raster Y width                                : 0
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.4198
    pressure fill bottle H2                  : 14.4274
    pressure ballast H2                      : 24.2161
    pressure exhaust H2                      : 14.4579
    cryogen input temp                       : 299.8
    crogen return flow                       : 1.14059
     JT valve setting                        : 98.6328
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1427.log:
    
       Cumulative stats for 2566 events: 
       
       Events failing cut conditions:
       0         Low_beam   2566
       1        Beam_burp      0
       2          Evt_seq      0
       3         Pair_seq      0
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------