    User name apar

    Log entry time 14:31:11 on February 26, 2010

    Entry number 310068

    keyword=End_of_Parity_Run_1471__CODA_Config=CHInj2
    ************************************************
     Run Number: 1471
     End of Run Comment:
    
    Run_type=Parityscan,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Injector Laser Studies:: lina vertical, vertical analyzer,PITA scan,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1471 at Fri Feb 26 14:28:45 EST 2010
    CODA Configuration: CHInj2
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       :  compton:RUN --- Invalid channel name
    -----------------------------------------
    Wien angle                               : 0
    Wien BDL                                 : 2098.1
    Wien field                               : 54.162
    Laser attenuation Hall A                 : 76
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 5.105
    Gun2: PC (PITA) NEG                      : 6.578
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 0.0952381
    Pockels Cell Voltage NEG                 : 0
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Pair
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Pair
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              :  COMPTON_LASERP_si --- Invalid channel name
    Calculated power in cavity               :  COMPTON_PW1PCAV_ca --- Invalid channel name
    Photodiode on table                      :  COMPTON_PW2PCAV_ca --- Invalid channel name
    Laser X position on QPD 1                :  COMPTON_Y1SS_ca --- Invalid channel name
    Laser Y position on QPD 1                :  COMPTON_X1SS_ca --- Invalid channel name
    Laser X position on QPD 2                :  COMPTON_Y2SS_ca --- Invalid channel name
    Laser Y position on QPD 2                :  COMPTON_X2SS_ca --- Invalid channel name
    QPD 1 sum                                :  COMPTON_XYSUM1_ca --- Invalid channel name
    QPD 2 sum                                :  COMPTON_XYSUM2_ca --- Invalid channel name
    Position set point for adjustable 
                   mirror 1 (either x or y)  :  COMPTON_POS1_si --- Invalid channel name
    Position set point for adjustable 
                   mirror 2 (either x or y)  :  COMPTON_POS3_si --- Invalid channel name
    Laser minimum temperature (35.8)         :  COMPTON_LASERT_MIN --- Invalid channel name
    Laser temperature set point              :  COMPTON_LASERT_si --- Invalid channel name
    Polarisation in cavity                   :  COMPTON_SU_POLAR_mo --- Invalid channel name
    Reflection photodiode                    :  COMPTON_SERVO_PDRai --- Invalid channel name
    Gain of locking servo                    :  COMPTON_SERVO_GAINao --- Invalid channel name
    Tracking level (V) of locking servo      :  COMPTON_SERVO_SEUILao --- Invalid channel name
    Slow locking signal sent to laser        :  COMPTON_SERVO_SLOWai --- Invalid channel name
    Fast locking signal sent to laser        :  COMPTON_SERVO_FASTai --- Invalid channel name
    Calculated polarisation in cavity        :  COMPTON_CAVPOLAR_ca --- Invalid channel name
    Photodiode 1 after Wollaston prism       :  COMPTON_PW1R_S1_ca --- Invalid channel name
    Photodiode 2 after Wollaston prism       :  COMPTON_PW1R_S2_ca --- Invalid channel name
    Step size for RHWP scan                  :  COMPTON_PVAL_Y_ao --- Invalid channel name
    Laser temp slow ramp (1 = on)            :  COMPTON_CAVSLOW_bo --- Invalid channel name
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         :  COMPTON_CAVPLUSOFT_ca.B --- Invalid channel name
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.0005883
    Left Arm Q1 gauss meter                  : 0.0002714
    Left Arm Q1 power supply polarity        : 0
    Left Arm Q2 power supply current         : -0.000475462
    Left Arm Q2 momentum                     : -1.23383e-06
    Left Arm Q2 gauss meter                  : 0.001051
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00223404
    Left Arm D1 momentum                     : 0.00255547
    Left Arm D1 NMR                          : 0.270361
    Left Arm Q3 power supply current         : -0.000477716
    Left Arm Q3 momentum                     : -1.44168e-06
    Left Arm Q3 gauss meter                  : -0.00011857
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00247614
    Right Arm Q1 gauss meter                 : -6.67e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.000214449
    Right Arm Q2 momentum                    : -4.80785e-07
    Right Arm Q2 gauss meter                 : 0.0005253
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -0.00354421
    Right Arm D1 momentum                    : 0.00464285
    Right Arm D1 NMR                         : 6.85799
    Right Arm Q3 power supply current        : 7.09898e-05
    Right Arm Q3 momentum                    : 0.0019288
    Right Arm Q3 gauss meter                 : 4.46e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0232992
    Current on Unser monitor                 : 17.678
    Current on Upstream bcm                  : 0.0343885
    Current on Downstream bcm                : 0.0122098
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00210003
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 24271.1
    MBSY3c Hall C Beam energy                : 8874.29
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 6.05688e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0
    Raster Y width                                : 0
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.4671
    pressure fill bottle H2                  : 14.406
    pressure ballast H2                      : 24.3977
    pressure exhaust H2                      : 14.4808
    cryogen input temp                       : 299.8
    crogen return flow                       : 0
     JT valve setting                        : 98.584
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 0
    No HAPPEX feedback runlog entry for Run #1471
      Was feedback on?