NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 18:43:28 on February 28, 2010
Entry number 310236
keyword=End_of_Parity_Run_1531__CODA_Config=CHInj2
************************************************
Run Number: 1531
End of Run Comment:
Run_type=Parityscan,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Injector Laser Studies::PC translation scan Y, RHWP=2400, 120 Hz, new cathode, vertical beam,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1531 at Sun Feb 28 18:43:20 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22110
-----------------------------------------
Wien angle : 0
Wien BDL : 2098.1
Wien field : 54.162
Laser attenuation Hall A : 110
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2400
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 4.582
Gun2: PC (PITA) NEG : 7.101
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 3.13553
Pockels Cell Voltage NEG : 2.93284
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 120.048
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 21mW
Calculated power in cavity : 0.979109
Photodiode on table : -0.041999
Laser X position on QPD 1 : -88.7355
Laser Y position on QPD 1 : 81.6931
Laser X position on QPD 2 : 7.18684e+06
Laser Y position on QPD 2 : -7.24956e+06
QPD 1 sum : -0.00610396
QPD 2 sum : -7.45058e-08
Position set point for adjustable
mirror 1 (either x or y) : -11965[c]
Position set point for adjustable
mirror 2 (either x or y) : -74075[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +50.4298
Polarisation in cavity : RIGHT
Reflection photodiode : 0.00549346
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.00915572
Fast locking signal sent to laser : 0.00549339
Calculated polarisation in cavity : 15.9747
Photodiode 1 after Wollaston prism : 0.0448728
Photodiode 2 after Wollaston prism : 0.032511
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.0534066
Left Arm Q1 momentum : 0.0008183
Left Arm Q1 gauss meter : 0.0002567
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : -0.000314479
Left Arm Q2 momentum : -7.05049e-07
Left Arm Q2 gauss meter : 0.0010547
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00211966
Left Arm D1 momentum : 0.00256187
Left Arm D1 NMR : 0.270418
Left Arm Q3 power supply current : -0.000650747
Left Arm Q3 momentum : -1.29901e-06
Left Arm Q3 gauss meter : -0.00012334
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00206787
Right Arm Q1 gauss meter : -5.38e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.00026991
Right Arm Q2 momentum : -6.05126e-07
Right Arm Q2 gauss meter : 0.0005355
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00315237
Right Arm D1 momentum : 0.00466492
Right Arm D1 NMR : 6.8592
Right Arm Q3 power supply current : 0.0119823
Right Arm Q3 momentum : 0.00194224
Right Arm Q3 gauss meter : 4.7e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0233208
Current on Unser monitor : 19.5956
Current on Upstream bcm : 0.0344728
Current on Downstream bcm : 0.0121689
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00330085
Tiefenbach Hall A energy : 0
Tiefenbach Hall C energy : 0
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 7172.88
MBSY3c Hall C Beam energy : 8874.29
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.79e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5006
pressure fill bottle H2 : 14.4701
pressure ballast H2 : 23.8285
pressure exhaust H2 : 14.6609
cryogen input temp : 299.8
crogen return flow : 0.104885
JT valve setting : 98.3398
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #1531
Was feedback on?