NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 09:14:06 on March 2, 2010
Entry number 310373
keyword=End_of_Parity_Run_1569__CODA_Config=Prex
************************************************
Run Number: 1569
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=PMT test - HV=1500, DAC16=17090, pulse on,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1569 at Tue Mar 2 09:13:58 EST 2010
CODA Configuration: Prex
Compton Run Number : 22110
-----------------------------------------
Wien angle : 0
Wien BDL : -30
Wien field : 0.1
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 0
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 5.682
Gun2: PC (PITA) NEG : 6.001
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.61783
Pockels Cell Voltage NEG : 2.42979
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity : 242.917
Photodiode on table : 224.227
Laser X position on QPD 1 : 542.239
Laser Y position on QPD 1 : -89.1279
Laser X position on QPD 2 : 144.538
Laser Y position on QPD 2 : -663.717
QPD 1 sum : -0.0109871
QPD 2 sum : -0.322285
Position set point for adjustable
mirror 1 (either x or y) : -1110000[c]
Position set point for adjustable
mirror 2 (either x or y) : 53620[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point :
Polarisation in cavity : RIGHT
Reflection photodiode : 0.00671424
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.0128181
Fast locking signal sent to laser : 0.00915572
Calculated polarisation in cavity : 0.675777
Photodiode 1 after Wollaston prism : 9.34137
Photodiode 2 after Wollaston prism : 9.46848
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000890273
Left Arm Q1 gauss meter : 0.0002521
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000359404
Left Arm Q2 momentum : -8.0577e-07
Left Arm Q2 gauss meter : 0.0011039
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00212681
Left Arm D1 momentum : 0.00321688
Left Arm D1 NMR : 0.270427
Left Arm Q3 power supply current : -0.000530378
Left Arm Q3 momentum : -8.86031e-07
Left Arm Q3 gauss meter : -0.00013386
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00161718
Right Arm Q1 gauss meter : -5.05e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0193448
Right Arm Q2 momentum : -4.33701e-05
Right Arm Q2 gauss meter : 0.0005246
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00338889
Right Arm D1 momentum : 0.00467555
Right Arm D1 NMR : 6.85952
Right Arm Q3 power supply current : -0.00569786
Right Arm Q3 momentum : -1.28657e-05
Right Arm Q3 gauss meter : 5.23e-05
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0230515
Current on Unser monitor : 18.2811
Current on Upstream bcm : 0.0337825
Current on Downstream bcm : 0.0123205
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00386746
Tiefenbach Hall A energy : 397.035
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0.586795
MBSY1c Hall A Beam energy : 396.694
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 98995.4
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B :
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.5647
pressure fill bottle H2 : 14.6166
pressure ballast H2 : 24.2329
pressure exhaust H2 : 14.6471
cryogen input temp : 299.8
crogen return flow : 0.0501427
JT valve setting : 98.291
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1569.log:
Cumulative stats for 130880 events:
Events failing cut conditions:
0 Low_beam 65641
1 Beam_burp 101677
2 Evt_seq 438
3 Pair_seq 2403
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------