User name apar
Log entry time 16:20:08 on March 3, 2010
Entry number 310534
keyword=End_of_Parity_Run_1613__CODA_Config=CHInj2
************************************************
Run Number: 1613
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Source Studies:: vertical lina,analyzer in, rhwp scan,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1613 at Wed Mar 3 16:20:02 EST 2010
CODA Configuration: CHInj2
# Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22110
-----------------------------------------
Wien angle : -1.3054
Wien BDL : 2149
Wien field : 55.48
Laser attenuation Hall A : 85
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 9000
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.901
Gun2: PC (PITA) NEG : 7.371
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.71551
Pockels Cell Voltage NEG : 2.55922
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Pair
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Pair
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 90mW
Calculated power in cavity : 1.37482
Photodiode on table : 585.244
Laser X position on QPD 1 : -147.891
Laser Y position on QPD 1 : -65.3627
Laser X position on QPD 2 : 118.526
Laser Y position on QPD 2 : -686.978
QPD 1 sum : -0.00366241
QPD 2 sum : -1.02545
Position set point for adjustable
mirror 1 (either x or y) : -1120000[c]
Position set point for adjustable
mirror 2 (either x or y) : -75275[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +50.4018
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0604285
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 8.72185
Calculated polarisation in cavity : 11.3218
Photodiode 1 after Wollaston prism : 0.0603213
Photodiode 2 after Wollaston prism : 0.0480515
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000934082
Left Arm Q1 gauss meter : 0.0002545
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000363148
Left Arm Q2 momentum : -1.04918e-06
Left Arm Q2 gauss meter : 0.001111
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00214825
Left Arm D1 momentum : 0.0031459
Left Arm D1 NMR : 0.270334
Left Arm Q3 power supply current : -0.000458908
Left Arm Q3 momentum : -1.16385e-06
Left Arm Q3 gauss meter : -0.00012858
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00159597
Right Arm Q1 gauss meter : -6.02e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000103527
Right Arm Q2 momentum : -2.40555e-07
Right Arm Q2 gauss meter : 0.0005352
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.00338536
Right Arm D1 momentum : 0.00470171
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -0.000127034
Right Arm Q3 momentum : -3.19255e-07
Right Arm Q3 gauss meter : 5.53e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0216323
Current on Unser monitor : 19.1419
Current on Upstream bcm : 0.0311718
Current on Downstream bcm : 0.0120928
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00183644
Tiefenbach Hall A energy : 397.035
Tiefenbach Hall C energy : 7128.6
Delta(E)/E width (MV_AI_DXWID) : 0.618897
MBSY1c Hall A Beam energy : 396.694
MBSY3c Hall C Beam energy : 7157.07
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 98995.4
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.3908
pressure fill bottle H2 : 14.3328
pressure ballast H2 : 24.2237
pressure exhaust H2 : 14.5113
cryogen input temp : 299.8
crogen return flow : 0.182079
JT valve setting : 98.4375
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_1613.log