    User name apar

    Log entry time 14:52:31 on March 4, 2010

    Entry number 310714

    keyword=End_of_Parity_Run_1679__CODA_Config=CHInj2
    ************************************************
     Run Number: 1679
     End of Run Comment:
    
    Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=injector studies:: PC ON, 120Hz, Polarization right, RHWP scan, 80-100, PITA=150,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=out,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1679 at Thu Mar  4 14:52:15 EST 2010
    CODA Configuration: CHInj2
    
    # Timing board information: # Integrate Time = 33.25 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : 0.1584
    Wien BDL                                 : 2149
    Wien field                               : 55.48
    Laser attenuation Hall A                 : 125
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 4900
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 9.976
    Gun2: PC (PITA) NEG                      : 5.296
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.58364
    Pockels Cell Voltage NEG                 : 2.41514
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 100
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 120.048
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 21mW
    Calculated power in cavity               : 0.988661
    Photodiode on table                      : 1402.54
    Laser X position on QPD 1                : -147.891
    Laser Y position on QPD 1                : 163.384
    Laser X position on QPD 2                : 776.036
    Laser Y position on QPD 2                : -4.3355
    QPD 1 sum                                : -0.00366241
    QPD 2 sum                                : -2.14369
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -2648[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 58920[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2010
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0494415
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.144662
    Fast locking signal sent to laser        : -0.686688
    Calculated polarisation in cavity        : 16.0739
    Photodiode 1 after Wollaston prism       : 0.0478983
    Photodiode 2 after Wollaston prism       : 0.0346323
    Step size for RHWP scan                  : 3750
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 0.01
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000761973
    Left Arm Q1 gauss meter                  : 0.0002603
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000205909
    Left Arm Q2 momentum                     : -4.61639e-07
    Left Arm Q2 gauss meter                  : 0.001106
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -0.00201957
    Left Arm D1 momentum                     : 0.00314395
    Left Arm D1 NMR                          : 0.270388
    Left Arm Q3 power supply current         : -0.000677078
    Left Arm Q3 momentum                     : -1.55431e-06
    Left Arm Q3 gauss meter                  : -0.00012488
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00127253
    Right Arm Q1 gauss meter                 : -3.35e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.00103157
    Right Arm Q2 momentum                    : -2.39696e-06
    Right Arm Q2 gauss meter                 : 0.0005421
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.88292
    Right Arm D1 momentum                    : 0.00470962
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : 0.000590336
    Right Arm Q3 momentum                    : 0.00198757
    Right Arm Q3 gauss meter                 : 5.51e-05
    Right Arm Q3 power supply polarity       : enabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0219921
    Current on Unser monitor                 : 16.7842
    Current on Upstream bcm                  : 0.0315828
    Current on Downstream bcm                : 0.0123218
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.000509302
    Tiefenbach Hall A energy                 : 397.035
    Tiefenbach Hall C energy                 : 7128.6
    Delta(E)/E width (MV_AI_DXWID)           : 0.633456
    MBSY1c Hall A Beam energy                : 396.694
    MBSY3c Hall C Beam energy                : 7157.07
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 98995.4
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0.2
    Raster Y width                                : 0.2
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.4121
    pressure fill bottle H2                  : 14.4747
    pressure ballast H2                      : 24.1825
    pressure exhaust H2                      : 14.5647
    cryogen input temp                       : 299.8
    crogen return flow                       : 0.113229
     JT valve setting                        : 98.4375
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1679.log:
    
       Cumulative stats for 16397 events: 
       
       Events failing cut conditions:
       0         Low_beam      2
       1        Beam_burp      1
       2          Evt_seq      1
       3         Pair_seq      5
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------