User name apar
Log entry time 17:31:39 on March 7, 2010
Entry number 311000
keyword=End_of_Parity_Run_1780__CODA_Config=Prex
End-of-Parity-run EPICS data for Run Number 1780 at Sun Mar 7 17:31:31 EST 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2149
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7456
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -47.1097
Wien BDL (Gcm) : -1089.5
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 29.741
Laser attenuation Hall A : 60
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 2500
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.976
Gun2: PC (PITA) NEG : 8.296
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.58608
Pockels Cell Voltage NEG : 2.37851
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 21mW
Calculated power in cavity : 1.13306
Photodiode on table : 511.466
Laser X position on QPD 1 : 665.481
Laser Y position on QPD 1 : -84.7258
Laser X position on QPD 2 : 76.4412
Laser Y position on QPD 2 : -761.621
QPD 1 sum : -0.0317403
QPD 2 sum : -0.421168
Position set point for adjustable
mirror 1 (either x or y) : -1962[c]
Position set point for adjustable
mirror 2 (either x or y) : -78955[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2010
Polarisation in cavity : RIGHT
Reflection photodiode : -10
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 6.64164
Calculated polarisation in cavity : 5.60178
Photodiode 1 after Wollaston prism : 0.0454886
Photodiode 2 after Wollaston prism : 0.0401859
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : 0.01
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000993538
Left Arm Q1 gauss meter : 0.0002455
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000366892
Left Arm Q2 momentum : -5.20393e-07
Left Arm Q2 gauss meter : 0.0011029
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -0.00225191
Left Arm D1 momentum : 0.00322273
Left Arm D1 NMR : 0.270394
Left Arm Q3 power supply current : -0.000470193
Left Arm Q3 momentum : -1.2915e-06
Left Arm Q3 gauss meter : -0.00011871
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000678685
Right Arm Q1 gauss meter : -3.28e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 59.7515
Right Arm Q2 momentum : 0.139751
Right Arm Q2 gauss meter : 0.0316
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0419375
Right Arm D1 momentum : 0.00490802
Right Arm D1 NMR : 0
Right Arm Q3 power supply current : -0.00020176
Right Arm Q3 momentum : -5.07052e-07
Right Arm Q3 gauss meter : 5.47e-05
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0273032
Current on Unser monitor : 17.7725
Current on Upstream bcm : 0.0348493
Current on Downstream bcm : 0.019757
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.012199
Tiefenbach Hall A energy : 4051.26
Tiefenbach Hall C energy : 5059.75
Delta(E)/E width (MV_AI_DXWID) : 6.91197
MBSY1c Hall A Beam energy : 4059.04
MBSY3c Hall C Beam energy : 5075.43
MBSY1c magnet current (amp) : 169.173
MBSY1c Bdl : 1.01294e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.7448
pressure fill bottle H2 : 14.6838
pressure ballast H2 : 23.7369
pressure exhaust H2 : 14.7097
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 98.0957
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_1780.log:
Cumulative stats for 27593 events:
Events failing cut conditions:
0 Low_beam 11323
1 Beam_burp 22640
2 Evt_seq 97
3 Pair_seq 565
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------