    User name apar

    Log entry time 17:04:24 on March 14, 2010

    Entry number 311595

    keyword=End_of_Parity_Run_1972__CODA_Config=Prex
    ************************************************
     Run Number: 1972
     End of Run Comment:
    
    Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=Gain calibration for PMT ZK5553 (resume from -850V),dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 1972 at Sun Mar 14 17:04:14 EDT 2010
    CODA Configuration: Prex
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 22283
    -----------------------------------------
    Wien angle (Vertical)                    : 88.8235
    Wien Vertical BDL (Gcm)                  : 2152.7
    Wien HV Polarity                         : OFF
    Wien electrode Voltage                   : 55.48
    Wien angle (Solenoids)                   : 90.7455
    Wien BDL (First Solenoid) (Gcm)          : 876.345
    Wien BDL (Second Solenoid) (Gcm)         : 876.346
    Wien angle (Horizontal)                  : -47.1097
    Wien BDL (Gcm)                           : -1085.6
    Wien HV Polarity (Horizontal)            : ON
    Wien electrode Voltage (Horizontal)      : 29.741
    Laser attenuation Hall A                 : 60
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 2350
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5.2
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 6.776
    Gun2: PC (PITA) NEG                      : 8.496
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.40293
    Pockels Cell Voltage NEG                 : 2.22466
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 16 windows
    Helicity Pattern Set                     : Octet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 100
    Helicity Stable Read                     : 4067
    Helicity Delay Read                      : 16 windows
    Helicity Pattern Read                    : Octet
    Helicity Frequency                       : 239.981
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 79mW
    Calculated power in cavity               : 0.927275
    Photodiode on table                      : 0.00135906
    Laser X position on QPD 1                : -110.919
    Laser Y position on QPD 1                : -81.7031
    Laser X position on QPD 2                : 438.596
    Laser Y position on QPD 2                : 7.25044e+06
    QPD 1 sum                                : -0.00488319
    QPD 2 sum                                : -0.00122085
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 775[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -955[c]
    Laser minimum temperature (35.8)         : 32.201
    Laser temperature set point              : +47.181
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0421168
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -2.31276
    Calculated polarisation in cavity        : 22.5306
    Photodiode 1 after Wollaston prism       : 0.0448996
    Photodiode 2 after Wollaston prism       : 0.0283876
    Step size for RHWP scan                  : 3750
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         : 0.015
    Speed of laser temp slow ramp down       : 0.015
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000898096
    Left Arm Q1 gauss meter                  : 0.0002571
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : -0.000269553
    Left Arm Q2 momentum                     : -6.04327e-07
    Left Arm Q2 gauss meter                  : 0.001045
    Left Arm Q2 power supply polarity        : enabled
    Left Arm D1 power supply current         : -1.34687
    Left Arm D1 momentum                     : 0.00318375
    Left Arm D1 NMR                          : 0.270315
    Left Arm Q3 power supply current         : -0.000842586
    Left Arm Q3 momentum                     : -1.08877e-06
    Left Arm Q3 gauss meter                  : -0.00011092
    Left Arm Q3 power supply polarity        : enabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00287911
    Right Arm Q1 gauss meter                 : -7.43e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0163092
    Right Arm Q2 momentum                    : -3.74579e-05
    Right Arm Q2 gauss meter                 : 0.000534
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 2.03039
    Right Arm D1 momentum                    : 0.00655166
    Right Arm D1 NMR                         : 0.198096
    Right Arm Q3 power supply current        : 0.0988439
    Right Arm Q3 momentum                    : 0.00269842
    Right Arm Q3 gauss meter                 : 0.0001821
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0221727
    Current on Unser monitor                 : 19.3947
    Current on Upstream bcm                  : 0.0312586
    Current on Downstream bcm                : 0.0130867
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 7.33796
    Tiefenbach Hall A energy                 : 1056.63
    Tiefenbach Hall C energy                 : 5059.75
    Delta(E)/E width (MV_AI_DXWID)           : 2.03382
    MBSY1c Hall A Beam energy                : 1057.43
    MBSY3c Hall C Beam energy                : 5075.43
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 263884
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0.2
    Raster Y width                                : 0.2
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L2 20cm
    Encoder position                         : 0
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 0
    temperature loop 3-2                     : 0
    temperature loop 3-3                     : 0
    pressure fill target H2                  : 14.345
    pressure fill bottle H2                  : 14.4518
    pressure ballast H2                      : 24.2359
    pressure exhaust H2                      : 14.4198
    cryogen input temp                       : 299.8
    crogen return flow                       : 0.112953
     JT valve setting                        : 54.3945
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_1972.log:
    
       Cumulative stats for 83797 events: 
       
       Events failing cut conditions:
       0         Low_beam      2
       1        Beam_burp    217
       2          Evt_seq    253
       3         Pair_seq   1412
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------