• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name A. Camsonne

    Log entry time 19:38:50 on March 14, 2010

    Entry number 311606

    This entry is a followup to: 311600

    keyword=By passed discriminator for Quartz on Cer adc channel 4

    I tried to move the signal to different input looking at the output on the scope and the signal is attenuated and distorted a lot. I have seen that with some PMTs, Piotr told me that one of the base was a bit different ( a capacitor missing on the HV side ) so that might be the reason. So I am trying without the discriminator for now. If it works we could put it in a linear fan or try swapping the base.

    A copy of this log entry has been emailed to: kkumar@physics.umass.edu, camsonne@jlab.org, pdecowsk@jlab.org