User name apar
Log entry time 10:30:14 on March 15, 2010
Entry number 311635
keyword=End_of_Parity_Run_1980__CODA_Config=Prex
************************************************
Run Number: 1980
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=feedback test,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 1980 at Mon Mar 15 10:30:08 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22295
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7455
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -47.1097
Wien BDL (Gcm) : -1091.2
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 29.741
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.776
Gun2: PC (PITA) NEG : 8.496
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.55678
Pockels Cell Voltage NEG : 2.34921
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 15mW
Calculated power in cavity : 0.0068826
Photodiode on table : -6.69444e-05
Laser X position on QPD 1 : -443.656
Laser Y position on QPD 1 : 108.924
Laser X position on QPD 2 : -438.65
Laser Y position on QPD 2 : 1327.49
QPD 1 sum : -0.00366241
QPD 2 sum : 0.0012207
Position set point for adjustable
mirror 1 (either x or y) : 1485[c]
Position set point for adjustable
mirror 2 (either x or y) : -55[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.168
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0445583
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -0.492584
Calculated polarisation in cavity : 205.161
Photodiode 1 after Wollaston prism : 0.00141901
Photodiode 2 after Wollaston prism : -0.000286021
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) :
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000841769
Left Arm Q1 gauss meter : 0.0002552
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000370636
Left Arm Q2 momentum : -1.20026e-06
Left Arm Q2 gauss meter : 0.0010451
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.34422
Left Arm D1 momentum : 0.00318208
Left Arm D1 NMR : 0.371014
Left Arm Q3 power supply current : -0.0023773
Left Arm Q3 momentum : -3.94209e-06
Left Arm Q3 gauss meter : -0.00010811
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00154295
Right Arm Q1 gauss meter : -4.91e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0164349
Right Arm Q2 momentum : -3.65644e-05
Right Arm Q2 gauss meter : 0.0005304
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.02912
Right Arm D1 momentum : 0.00625187
Right Arm D1 NMR : 0.484835
Right Arm Q3 power supply current : 0.0984965
Right Arm Q3 momentum : 0.00269562
Right Arm Q3 gauss meter : 0.0001816
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0222374
Current on Unser monitor : 18.5823
Current on Upstream bcm : 0.0312169
Current on Downstream bcm : 0.0132578
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00266272
Tiefenbach Hall A energy : 1056.63
Tiefenbach Hall C energy : 5059.75
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1057.43
MBSY3c Hall C Beam energy : 5075.43
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 263884
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0.2
Raster Y width : 0.2
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.3664
pressure fill bottle H2 : 14.4945
pressure ballast H2 : 24.1764
pressure exhaust H2 : 14.4182
cryogen input temp : 299.8
crogen return flow : 0
JT valve setting : 54.1992
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_1980.log