NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 22:18:27 on March 18, 2010
Entry number 312056
keyword=End_of_Parity_Run_2112__CODA_Config=Prex
************************************************
Run Number: 2112
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=on,comment_text=DAQ test,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 2112 at Thu Mar 18 22:18:21 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22348
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7455
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -58.9992
Wien BDL (Gcm) : -1354.1
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 37.247
Laser attenuation Hall A : 85
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.9
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.776
Gun2: PC (PITA) NEG : 8.496
Gun3: PC (PITA) POS : 5
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.78877
Pockels Cell Voltage NEG : 2.59096
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 84mW
Calculated power in cavity : 0.0467611
Photodiode on table : 1.34956
Laser X position on QPD 1 : -221.835
Laser Y position on QPD 1 : -163.404
Laser X position on QPD 2 : -7.18596e+06
Laser Y position on QPD 2 : -442.424
QPD 1 sum : -0.00244163
QPD 2 sum : -7.45058e-08
Position set point for adjustable
mirror 1 (either x or y) : -3385[c]
Position set point for adjustable
mirror 2 (either x or y) : -1155[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.200
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0579869
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -0.653727
Calculated polarisation in cavity : 3.3456
Photodiode 1 after Wollaston prism : 0.00381941
Photodiode 2 after Wollaston prism : 0.00357212
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) :
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00114844
Left Arm Q1 gauss meter : 0.0002452
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : -0.000250834
Left Arm Q2 momentum : -5.758e-07
Left Arm Q2 gauss meter : 0.0010606
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.34531
Left Arm D1 momentum : 0.00304457
Left Arm D1 NMR : 0.22612
Left Arm Q3 power supply current : -0.000188077
Left Arm Q3 momentum : -4.32393e-07
Left Arm Q3 gauss meter : -7.163e-05
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.00156946
Right Arm Q1 gauss meter : -4.96e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.000247725
Right Arm Q2 momentum : -5.67915e-07
Right Arm Q2 gauss meter : 0.0005258
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.88682
Right Arm D1 momentum : 0.0052664
Right Arm D1 NMR : 0.28361
Right Arm Q3 power supply current : 0.000183079
Right Arm Q3 momentum : 0.00249188
Right Arm Q3 gauss meter : 0.0001452
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0243931
Current on Unser monitor : 18.6224
Current on Upstream bcm : 0.0344273
Current on Downstream bcm : 0.0143589
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 5.90848
Tiefenbach Hall A energy : 1063.48
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 1.29282
MBSY1c Hall A Beam energy : 1064.31
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 265599
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 0
Raster Y width : 0
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L2 20cm
Encoder position : 0
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.4274
pressure fill bottle H2 : 14.4793
pressure ballast H2 : 24.0497
pressure exhaust H2 : 14.5464
cryogen input temp : 299.8
crogen return flow : 0.0733868
JT valve setting : 54.248
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_2112.log