• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 13:51:21 on March 22, 2010

    Entry number 312961

    keyword=End_of_Parity_Run_2204__CODA_Config=Prex
    ************************************************
     Run Number: 2204
     End of Run Comment:
    
    Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=off,comment_text=DAQ check - adcx problem???,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 2204 at Mon Mar 22 13:51:08 EDT 2010
    CODA Configuration: Prex
    
    
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle (Vertical)                    : 88.8235
    Wien Vertical BDL (Gcm)                  : 2152.7
    Wien HV Polarity                         : OFF
    Wien electrode Voltage                   : 55.48
    Wien angle (Solenoids)                   : 90.7455
    Wien BDL (First Solenoid) (Gcm)          : 876.345
    Wien BDL (Second Solenoid) (Gcm)         : 876.346
    Wien angle (Horizontal)                  : -58.9992
    Wien BDL (Gcm)                           : -1354.1
    Wien HV Polarity (Horizontal)            : ON
    Wien electrode Voltage (Horizontal)      : 37.247
    Laser attenuation Hall A                 : 95
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 2350
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5.1
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 6.776
    Gun2: PC (PITA) NEG                      : 8.496
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.52259
    Pockels Cell Voltage NEG                 : 2.34432
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 16 windows
    Helicity Pattern Set                     : Octet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 100
    Helicity Stable Read                     : 4067
    Helicity Delay Read                      : 16 windows
    Helicity Pattern Read                    : Octet
    Helicity Frequency                       : 239.981
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : -0.00198545
    Photodiode on table                      : 61.6959
    Laser X position on QPD 1                : 554.565
    Laser Y position on QPD 1                : -27.2346
    Laser X position on QPD 2                : -468.5
    Laser Y position on QPD 2                : 392.196
    QPD 1 sum                                : -0.0146494
    QPD 2 sum                                : -0.0537143
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 635[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : 2180[c]
    Laser minimum temperature (35.8)         : 32.201
    Laser temperature set point              : +46.972
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.0860648
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -1.92456
    Calculated polarisation in cavity        : 89.453
    Photodiode 1 after Wollaston prism       : -0.000148645
    Photodiode 2 after Wollaston prism       : -8.27518e-06
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         : 0.015
    Speed of laser temp slow ramp down       : 0.015
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 444.396
    Left Arm Q1 momentum                     : 1.05865
    Left Arm Q1 gauss meter                  : -0.03728
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 461.1
    Left Arm Q2 momentum                     : 1.05847
    Left Arm Q2 gauss meter                  : 0.2429
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 352.126
    Left Arm D1 momentum                     : 1.0584
    Left Arm D1 NMR                          : 0.39184
    Left Arm Q3 power supply current         : 460.324
    Left Arm Q3 momentum                     : 1.05829
    Left Arm Q3 gauss meter                  : -0.23227
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 435.317
    Right Arm Q1 momentum                    : 1.05853
    Right Arm Q1 gauss meter                 : -0.010958
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 461.628
    Right Arm Q2 momentum                    : 1.05829
    Right Arm Q2 gauss meter                 : 0.2415
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 362.771
    Right Arm D1 momentum                    : 1.05839
    Right Arm D1 NMR                         : 0.392756
    Right Arm Q3 power supply current        : 458.801
    Right Arm Q3 momentum                    : 1.05863
    Right Arm Q3 gauss meter                 : 0.2049
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0230579
    Current on Unser monitor                 : 18.604
    Current on Upstream bcm                  : 0.0324707
    Current on Downstream bcm                : 0.0136451
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.000929877
    Tiefenbach Hall A energy                 : 1060.52
    Tiefenbach Hall C energy                 : 5092.66
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 1061.34
    MBSY3c Hall C Beam energy                : 5108.41
    MBSY1c magnet current (amp)              : 43.916
    MBSY1c Bdl                               : 264859
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 0.2
    Raster Y width                                : 0.2
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : THIN Carbon
    Encoder position                         : 19187292
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 14.5068
    pressure fill bottle H2                  : 14.5174
    pressure ballast H2                      : 24.152
    pressure exhaust H2                      : 14.5739
    cryogen input temp                       : 3.7
    crogen return flow                       : 0.145217
     JT valve setting                        : -0.0488281
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_2204.log:
    
       Cumulative stats for 21700 events: 
       
       Events failing cut conditions:
       0         Low_beam  10855
       1        Beam_burp  21683
       2          Evt_seq      0
       3         Pair_seq   3464
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------