    User name A. Camsonne

    Log entry time 17:51:17 on March 22, 2010

    Entry number 313046

    keyword=N1470 HV control instructions

    To control the GEM HV,
    one has to log into the ahut computer using the adaq account and use minicom.
    
    Once in Minicom,
    type CAEN and carrier return.
    
    The menu will display, you should get : 
    
         ##   ##     ##      ####    ######    #####  
         ###  ##   ####     ## ##        ##   ##   ## 
         ## # ##     ##    #######      ##    ##   ## 
         ##  ###     ##        ##      ##     ##   ## 
         ##   ##    ####      ####    ##       #####  
    
         C.A.E.N.  N1470 4 Ch HV Power Supply    V1.00    Addr 00
    
         B O A R D   M E N U 
    
         Display            Display/Modify channels      
         Format             Reformat EEPROM              
         General            General board status         
         Update             Firmware Update              
    
    
    
         Quit 
    
    
    
         Select Item  
    ---------------
    Then type D to go in the control screen :
    
    C.A.E.N.  N1470 4 Ch HV Power Supply    V1.00     Addr 00
    
                       Ch0             Ch1             Ch2             Ch3
    
     Polarity           -               -               -               -
     Vmon            0000.0 V        0000.0 V        0000.0 V        0000.0 V
     Imon           000.000 uA      000.000 uA      000.000 uA      000.000 uA
     Status            PwF             PwF             PwF             PwF  
    
     Power             Off             Off             Off             Off 
     Vset            3750.0 V        4200.0 V        4200.0 V        0200.0 V 
     Iset           0310.00 uA      0100.00 uA      0310.00 uA      0310.00 uA 
     Maxv              3800 V          8100 V          8100 V          8100 V 
     Ramp Up            050 V/S         050 V/S         050 V/S         050 V/S 
     Ramp Down          050 V/S         050 V/S         050 V/S         050 V/S 
     Trip             010.0 S         010.0 S         010.0 S         010.0 S 
     Power Down        Kill            Kill            Kill            Kill 
     Imon Range        Low             Low             Low             Low  
    
    
    
     Group Mode    Reset Alarm     Quit 
    
    and use the arrows to modify values. And space to toggle things.
    