• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 15:39:33 on March 25, 2010

    Entry number 313674

    keyword=End_of_Parity_Run_2302__CODA_Config=Prex
    ************************************************
     Run Number: 2302
     End of Run Comment:
    
    Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=off,comment_text=dithering test,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 2302 at Thu Mar 25 15:39:28 EDT 2010
    CODA Configuration: Prex
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle (Vertical)                    : 88.8235
    Wien Vertical BDL (Gcm)                  : 2152.7
    Wien HV Polarity                         : OFF
    Wien electrode Voltage                   : 55.48
    Wien angle (Solenoids)                   : 90.7455
    Wien BDL (First Solenoid) (Gcm)          : 876.345
    Wien BDL (Second Solenoid) (Gcm)         : 876.346
    Wien angle (Horizontal)                  : -58.9992
    Wien BDL (Gcm)                           : -1350.5
    Wien HV Polarity (Horizontal)            : ON
    Wien electrode Voltage (Horizontal)      : 37.247
    Laser attenuation Hall A                 : 70
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 2350
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 4.9
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 6.776
    Gun2: PC (PITA) NEG                      : 8.496
    Gun3: PC (PITA) POS                      : 5
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.73993
    Pockels Cell Voltage NEG                 : 2.52991
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 16 windows
    Helicity Pattern Set                     : Octet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 100
    Helicity Stable Read                     : 4067
    Helicity Delay Read                      : 16 windows
    Helicity Pattern Read                    : Octet
    Helicity Frequency                       : 239.981
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : 
    Calculated power in cavity               : 0.102771
    Photodiode on table                      : 0.857895
    Laser X position on QPD 1                : -221.835
    Laser Y position on QPD 1                : -108.937
    Laser X position on QPD 2                : 438.596
    Laser Y position on QPD 2                : 7.25044e+06
    QPD 1 sum                                : -0.00244163
    QPD 2 sum                                : -0.00122085
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 705[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1795[c]
    Laser minimum temperature (35.8)         : 32.201
    Laser temperature set point              : 
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.040896
    Gain of locking servo                    : 168
    Tracking level (V) of locking servo      : 0.35
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -6.59037
    Calculated polarisation in cavity        : 5.95485
    Photodiode 1 after Wollaston prism       : 0.00381941
    Photodiode 2 after Wollaston prism       : 0.00430309
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : OFF
    Extent of laser temp slow ramp (C)       : 
    Speed of laser temp slow ramp up         : 0.015
    Speed of laser temp slow ramp down       : 0.015
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.694286
    Left Arm Q1 momentum                     : 0.00200898
    Left Arm Q1 gauss meter                  : 0.0001928
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0117817
    Left Arm Q2 momentum                     : 0.00130987
    Left Arm Q2 gauss meter                  : -0.0001458
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.26161
    Left Arm D1 momentum                     : 0.00472984
    Left Arm D1 NMR                          : 0.166887
    Left Arm Q3 power supply current         : 1.37611
    Left Arm Q3 momentum                     : 0.00809582
    Left Arm Q3 gauss meter                  : -0.00085303
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0.16022
    Right Arm Q1 momentum                    : 0.00177094
    Right Arm Q1 gauss meter                 : -6.1e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0135066
    Right Arm Q2 momentum                    : -3.22355e-05
    Right Arm Q2 gauss meter                 : 0.0004206
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 2.0251
    Right Arm D1 momentum                    : 0.0256343
    Right Arm D1 NMR                         : 0.203183
    Right Arm Q3 power supply current        : 0.0976035
    Right Arm Q3 momentum                    : 0.00334882
    Right Arm Q3 gauss meter                 : 0.0002983
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0236142
    Current on Unser monitor                 : 19.2758
    Current on Upstream bcm                  : 0.0327609
    Current on Downstream bcm                : 0.0144675
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.0299934
    Tiefenbach Hall A energy                 : 1060.52
    Tiefenbach Hall C energy                 : 5092.66
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 1061.34
    MBSY3c Hall C Beam energy                : 5108.41
    MBSY1c magnet current (amp)              : 1.33514e-05
    MBSY1c Bdl                               : 264859
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 8
    Raster Y width                                : 8
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Empty
    Encoder position                         : 13395292
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 14.432
    pressure fill bottle H2                  : 14.5205
    pressure ballast H2                      : 24.2527
    pressure exhaust H2                      : 14.5068
    cryogen input temp                       : 118.7
    crogen return flow                       : 6.24226
     JT valve setting                        : 0.585938
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
     Did not obtain HAPPEX feedback cumulative results from 
        /adaqfs/halla/apar/feedback/runlog/ffb_2302.log