NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 16:30:28 on March 26, 2010
Entry number 313881
keyword=End_of_Parity_Run_2316__CODA_Config=Prex
************************************************
Run Number: 2316
End of Run Comment:
Run_type=Test,beam_energy=0,beam_polarization=0,beam_raster=off,comment_text=Establish functionality,dithering_magnet=off,dithering_magnets=,leftarm_p=0,leftarm_theta=0,parity_feedback=off,parity_ihwp=in,rightarm_p=0,rightarm_theta=0,target_fanspeed=0 Hz,target_type=Empty
************************************************
Current on Upstream bcm : 0.423603
End-of-Parity-run EPICS data for Run Number 2316 at Fri Mar 26 16:30:16 EDT 2010
CODA Configuration: Prex
Current on Downstream bcm : 0.514247
Upstream Cavity Coefficient : 42.6
Compton Run Number : 0
-----------------------------------------
Downstream Cavity Coefficient : 43.8
Wien angle (Vertical) : 88.8235
Current on IBC0L02 (source) : 7.63529
Wien Vertical BDL (Gcm) : 2152.7
Tiefenbach Hall A energy : 1060.26
Wien HV Polarity : OFF
Tiefenbach Hall C energy : 5092.66
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7455
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Delta(E)/E width (MV_AI_DXWID) : 0
Wien angle (Horizontal) : -58.9992
MBSY1c Hall A Beam energy : 1061.34
Wien BDL (Gcm) : -1347
MBSY3c Hall C Beam energy : 5108.41
Wien HV Polarity (Horizontal) : ON
MBSY1c magnet current (amp) : 43.916
Wien electrode Voltage (Horizontal) : 37.247
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Laser attenuation Hall A : 59
Arc1 dp/p : 0
Laser power Hall A : 100
Arc2 dp/p : 0
Beam Half-wave plate Set(off=out) : IN
Raster X width : 5
Beam Half-wave plate Read(off=out) : IN
Raster Y width : 5
-----------------------------------------
Target BPMs
-----------------------------------------
Rotating waveplate : 2350
IPM1C12.XPOS : 0
IA Cell Setpoint Hall A : 4.96
IPM1C12.YPOS : 0
IA Cell Setpoint Hall C : 5
IPM1H04A.XPOS : -0.457206
PZT X Setpoint Hall A : 4
IPM1H04A.YPOS : 0.3602
PZT Y Setpoint Hall A : 4
IPM1H04B.XPOS : -2.09437
PZT X Setpoint Common :
IPM1H04B.YPOS : 2.98876
PZT Y Setpoint Common : 5
Survey X offset bpm4A : -0.63
Gun2: PC (PITA) POS : 6.776
Survey Y offset bpm4A : -0.9
Gun2: PC (PITA) NEG : 8.496
Survey X offset bpm4B : 0.77
Gun3: PC (PITA) POS : 5
Survey Y offset bpm4B : -1
Gun3: PC (PITA) NEG : 5
Survey X offset bpm12 : 0
Pockels Cell Voltage POS : 2.6862
Survey Y offset bpm12 : 0
Pockels Cell Voltage NEG : 2.52259
Survey X HI SAT bpm12 : 0
Helicity Clock Set : Free Clock
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Helicity Delay Set : 16 windows
Target : Carbon Hole
Helicity Pattern Set : Octet
Encoder position : 11932250
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
fan frequency loop 1 : 0
Helicity Stable Read : 4067
fan frequency loop 2 : 0
Helicity Delay Read : 16 windows
fan frequency loop 3 : 0
Helicity Pattern Read : Octet
temperature loop 1-1 : 119.99
Helicity Frequency : 239.981
temperature loop 1-2 : 119.99
-----------------------------------------
Compton stuffs
-----------------------------------------
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
Laser power :
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
Calculated power in cavity : 0.000763096
temperature loop 3-1 : 99.99
Photodiode on table : -0.104518
temperature loop 3-2 : 99.99
Laser X position on QPD 1 : -221.835
temperature loop 3-3 : 29.99
Laser Y position on QPD 1 : -108.937
pressure fill target H2 : 14.522
Laser X position on QPD 2 : 7.18684e+06
pressure fill bottle H2 : 14.5205
Laser Y position on QPD 2 : -221.259
pressure ballast H2 : 23.9582
QPD 1 sum : -0.00244163
pressure exhaust H2 : 14.6029
QPD 2 sum : -7.45058e-08
cryogen input temp : 119
Position set point for adjustable
crogen return flow : 6.0682
mirror 1 (either x or y) : Home (0[c])
JT valve setting : 0.439453
-----------------------------------------
Position set point for adjustable
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
mirror 2 (either x or y) : -1795[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point :
Polarisation in cavity : RIGHT
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_2316.log:
Cumulative stats for 50679 events:
Events failing cut conditions:
0 Low_beam 2
1 Beam_burp 9
2 Evt_seq 0
3 Pair_seq 2
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------
Reflection photodiode : 0.040896
Gain of locking servo : 168
Tracking level (V) of locking servo : 0.35
epicsRunEnd ... for run 2316
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -4.06336
Calculated polarisation in cavity : 346.974
Photodiode 1 after Wollaston prism : 2.01552e-05
Photodiode 2 after Wollaston prism : -0.000148953
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : OFF
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 446.319
Left Arm Q1 momentum : 1.06297
Left Arm Q1 gauss meter : -0.03738
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 463.111
Left Arm Q2 momentum : 1.06309
Left Arm Q2 gauss meter : 0.2437
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.921
Left Arm D1 momentum : 1.06301
Left Arm D1 NMR : 0.393542
Left Arm Q3 power supply current : 462.331
Left Arm Q3 momentum : 1.06291
Left Arm Q3 gauss meter : -0.23324
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 437.079
Right Arm Q1 momentum : 1.06281
Right Arm Q1 gauss meter : -0.01095
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.812
Right Arm Q2 momentum : 1.0633
Right Arm Q2 gauss meter : 0.2426
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.909
Right Arm D1 momentum : 1.06303
Right Arm D1 NMR : 0.394478
Right Arm Q3 power supply current : 460.643
Right Arm Q3 momentum : 1.06288
Right Arm Q3 gauss meter : 0.2057
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.471279
Current on Unser monitor : 19.5124
Current on Upstream bcm : 0.425975
Current on Downstream bcm : 0.516583
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 7.66082
Tiefenbach Hall A energy : 1060.27
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 5
Raster Y width : 5
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : -0.383564
IPM1H04A.YPOS : 0.344205
IPM1H04B.XPOS : -2.01414
IPM1H04B.YPOS : 3.00487
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Carbon Hole
Encoder position : 11932250
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 14.5647
pressure fill bottle H2 : 14.4915
pressure ballast H2 : 23.9857
pressure exhaust H2 : 14.6777
cryogen input temp : 119
crogen return flow : 6.18344
JT valve setting : 0.488281
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_2316.log:
Cumulative stats for 50679 events:
Events failing cut conditions:
0 Low_beam 2
1 Beam_burp 9
2 Evt_seq 0
3 Pair_seq 2
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------