• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 16:57:25 on March 31, 2010

    Entry number 315115

    keyword=End_of_Parity_Run_2434__CODA_Config=Prex
    ************************************************
     Run Number: 2434
     End of Run Comment:
    
    Run_type=Other,beam_current=0,beam_energy=1.063,beam_polarization=0,beam_raster=off,comment_text=test adcx0,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 2434 at Wed Mar 31 16:57:13 EDT 2010
    CODA Configuration: Prex
    
    # Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 22385
    -----------------------------------------
    Wien angle (Vertical)                    : 88.8235
    Wien Vertical BDL (Gcm)                  : 2152.7
    Wien HV Polarity                         : OFF
    Wien electrode Voltage                   : 55.48
    Wien angle (Solenoids)                   : 90.7456
    Wien BDL (First Solenoid) (Gcm)          : 876.345
    Wien BDL (Second Solenoid) (Gcm)         : 876.346
    Wien angle (Horizontal)                  : -58.9992
    Wien BDL (Gcm)                           : 
    Wien HV Polarity (Horizontal)            : ON
    Wien electrode Voltage (Horizontal)      : 37.247
    Laser attenuation Hall A                 : 65
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 2350
    IA Cell Setpoint  Hall A                 : 4.96
    IA Cell Setpoint  Hall B                 : 5.03541
    IA Cell Setpoint  Hall C                 : 5
    PZT X Setpoint  Hall A                   : 4
    PZT Y Setpoint  Hall A                   : 4
    PZT X Setpoint  Common                   : 5.045
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.594
    Gun2: PC (PITA) NEG                      : 7.678
    Pockels Cell ON/OFF                      : ON
    Pockels Cell X Stage                     : -0.0551
    Pockels Cell Y Stage                     : -0.03735
    Wager X Stage                            : 800
    Wager Y Stage                            : 775
    Hall A Slit Position                     : -0.996094
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 windows
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 110
    Helicity Stable Read                     : 5500
    Helicity Delay Read                      : 8 windows
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 178.253
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 79mW
    Calculated power in cavity               : 0.00242711
    Photodiode on table                      : 964.035
    Laser X position on QPD 1                : 782.675
    Laser Y position on QPD 1                : 21.9256
    Laser X position on QPD 2                : -748.055
    Laser Y position on QPD 2                : 98.6778
    QPD 1 sum                                : -0.388207
    QPD 2 sum                                : -3.61961
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -2795[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1275[c]
    Laser minimum temperature (35.8)         : 32.2
    Laser temperature set point              : +47.177
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 1.12983
    Gain of locking servo                    : 123.316
    Tracking level (V) of locking servo      : 0.28
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -7.00055
    Calculated polarisation in cavity        : 207.767
    Photodiode 1 after Wollaston prism       : 0.000559307
    Photodiode 2 after Wollaston prism       : 0.0012992
    Step size for RHWP scan                  : 50
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         : 0.015
    Speed of laser temp slow ramp down       : 0.015
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 582.506
    Left Arm Q1 momentum                     : 1.38732
    Left Arm Q1 gauss meter                  : -0.04885
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 458.577
    Left Arm Q2 momentum                     : 1.05268
    Left Arm Q2 gauss meter                  : 0.2412
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 353.82
    Left Arm D1 momentum                     : 1.06302
    Left Arm D1 NMR                          : 0.393548
    Left Arm Q3 power supply current         : 569.939
    Left Arm Q3 momentum                     : 1.3103
    Left Arm Q3 gauss meter                  : -0.28755
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 582.025
    Right Arm Q1 momentum                    : 1.4154
    Right Arm Q1 gauss meter                 : -0.014583
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 461.466
    Right Arm Q2 momentum                    : 1.05792
    Right Arm Q2 gauss meter                 : 0.2413
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 364.43
    Right Arm D1 momentum                    : 1.06301
    Right Arm D1 NMR                         : 0.394469
    Right Arm Q3 power supply current        : 570.986
    Right Arm Q3 momentum                    : 1.31749
    Right Arm Q3 gauss meter                 : 0.2552
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0233785
    Current on Unser monitor                 : 20.6384
    Current on Upstream bcm                  : 0.0331932
    Current on Downstream bcm                : 0.0135638
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.00072032
    Tiefenbach Hall A energy                 : 1060.52
    Tiefenbach Hall C energy                 : 5092.66
    Delta(E)/E width (MV_AI_DXWID)           : 2.68068
    MBSY1c Hall A Beam energy                : 1061.34
    MBSY3c Hall C Beam energy                : 5108.41
    MBSY1c magnet current (amp)              : 43.916
    MBSY1c Bdl                               : 264859
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 10
    Raster Y width                                : 4.8
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : 0.24
    Survey Y offset bpm4A                     : 0.36
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : 1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Empty
    Encoder position                         : 13395291
    fan frequency loop 1                     : 0
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 119.99
    temperature loop 1-2                     : 119.99
    temperature loop 1-3                     : 119.99
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 14.6609
    pressure fill bottle H2                  : 14.6136
    pressure ballast H2                      : 24.2573
    pressure exhaust H2                      : 14.6258
    cryogen input temp                       : 122.2
    crogen return flow                       : 5.8571
     JT valve setting                        : 0.292969
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_2434.log:
    
       Cumulative stats for 21141 events: 
       
       Events failing cut conditions:
       0         Low_beam      0
       1        Beam_burp      0
       2          Evt_seq      0
       3         Pair_seq    274
       4          Startup      1
       5    Adcx_DAC_burp      2
       
       
       --------------------------------------------------