Log entry time 16:57:25 on March 31, 2010
Entry number 315115
keyword=End_of_Parity_Run_2434__CODA_Config=Prex
************************************************
Run Number: 2434
End of Run Comment:
Run_type=Other,beam_current=0,beam_energy=1.063,beam_polarization=0,beam_raster=off,comment_text=test adcx0,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
************************************************
End-of-Parity-run EPICS data for Run Number 2434 at Wed Mar 31 16:57:13 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22385
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7456
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -58.9992
Wien BDL (Gcm) :
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 37.247
Laser attenuation Hall A : 65
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 5.03541
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5.045
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.594
Gun2: PC (PITA) NEG : 7.678
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0551
Pockels Cell Y Stage : -0.03735
Wager X Stage : 800
Wager Y Stage : 775
Hall A Slit Position : -0.996094
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 110
Helicity Stable Read : 5500
Helicity Delay Read : 8 windows
Helicity Pattern Read : Quartet
Helicity Frequency : 178.253
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity : 0.00242711
Photodiode on table : 964.035
Laser X position on QPD 1 : 782.675
Laser Y position on QPD 1 : 21.9256
Laser X position on QPD 2 : -748.055
Laser Y position on QPD 2 : 98.6778
QPD 1 sum : -0.388207
QPD 2 sum : -3.61961
Position set point for adjustable
mirror 1 (either x or y) : -2795[c]
Position set point for adjustable
mirror 2 (either x or y) : -1275[c]
Laser minimum temperature (35.8) : 32.2
Laser temperature set point : +47.177
Polarisation in cavity : RIGHT
Reflection photodiode : 1.12983
Gain of locking servo : 123.316
Tracking level (V) of locking servo : 0.28
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -7.00055
Calculated polarisation in cavity : 207.767
Photodiode 1 after Wollaston prism : 0.000559307
Photodiode 2 after Wollaston prism : 0.0012992
Step size for RHWP scan : 50
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.506
Left Arm Q1 momentum : 1.38732
Left Arm Q1 gauss meter : -0.04885
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 458.577
Left Arm Q2 momentum : 1.05268
Left Arm Q2 gauss meter : 0.2412
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.82
Left Arm D1 momentum : 1.06302
Left Arm D1 NMR : 0.393548
Left Arm Q3 power supply current : 569.939
Left Arm Q3 momentum : 1.3103
Left Arm Q3 gauss meter : -0.28755
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.025
Right Arm Q1 momentum : 1.4154
Right Arm Q1 gauss meter : -0.014583
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 461.466
Right Arm Q2 momentum : 1.05792
Right Arm Q2 gauss meter : 0.2413
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.43
Right Arm D1 momentum : 1.06301
Right Arm D1 NMR : 0.394469
Right Arm Q3 power supply current : 570.986
Right Arm Q3 momentum : 1.31749
Right Arm Q3 gauss meter : 0.2552
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0233785
Current on Unser monitor : 20.6384
Current on Upstream bcm : 0.0331932
Current on Downstream bcm : 0.0135638
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00072032
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 2.68068
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 10
Raster Y width : 4.8
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 13395291
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 14.6609
pressure fill bottle H2 : 14.6136
pressure ballast H2 : 24.2573
pressure exhaust H2 : 14.6258
cryogen input temp : 122.2
crogen return flow : 5.8571
JT valve setting : 0.292969
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_2434.log:
Cumulative stats for 21141 events:
Events failing cut conditions:
0 Low_beam 0
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 274
4 Startup 1
5 Adcx_DAC_burp 2
--------------------------------------------------