• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 04:02:06 on April 1,2010

    Entry number 315272

    keyword=scan of septum, tune B

    Scan of septum current for tune B.

    I verified the gaussmeters are identical to last night,
    so it is tune B

    Super-thin C12 target. Raster off. beam = 0.5 uA.
    Using T1 and T5 triggers.

    VDCs off. Take a series of runs just to record the scalers
    in the datastream.

    Septum current .... HRS runs ..... Rates (kHz)
    (Amps) ....... Left .... Right ... Left HRS ....... Right HRS
    .................................. T1 .... T5 ..... T1 ..... T5

    719.86 ....... 27153 ... 6488 ... 55 .... 82 .... 92.5 .... 150

    600 .......... 27154 ... 6489 ... 42.5 ... 6.5 ... 66 ..... 7.5

    640 .......... 27155 ... 6490 ... 47.6 ... 19.5 .. 76.5 ... 25

    660 .......... 27156 ... 6491 ... 50 ..... 39 .... 80 ..... 43

    680 .......... 27157 ... 6492 ... 52.5 ... 70 .... 85 ..... 80

    700 .......... 27158 ... 6493 ... 54.6 ... 78 .... 89.5 ... 137

    720 .......... 27159 ... 6494 ... 56.5 ... 81.5 .. 93 ..... 150

    740 .......... 27160 ... 6495 ... 59.5 ... 81.5 .. 95 ..... 155

    760 .......... 27161 ... 6496 ... 62 ..... 72 .... 98 ..... 153

    780 .......... 27162 ... 6497 ... 63 ..... 32 .... 99.5 ... 143

    800 .......... 27163 ... 6498 ... 64 ..... 13.8 .. 100 .... 88

    719.86 .......................... 57.5 ... 81.5 ... 93 .... 150