Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name R. Michaels
Log entry time 04:02:06 on April 1,2010
Entry number 315272
keyword=scan of septum, tune B
Scan of septum current for tune B.
I verified the gaussmeters are identical to last night,
so it is tune B
Super-thin C12 target. Raster off. beam = 0.5 uA.
Using T1 and T5 triggers.
VDCs off. Take a series of runs just to record the scalers
in the datastream.
Septum current .... HRS runs ..... Rates (kHz)
(Amps) ....... Left .... Right ... Left HRS ....... Right HRS
.................................. T1 .... T5 ..... T1 ..... T5
719.86 ....... 27153 ... 6488 ... 55 .... 82 .... 92.5 .... 150
600 .......... 27154 ... 6489 ... 42.5 ... 6.5 ... 66 ..... 7.5
640 .......... 27155 ... 6490 ... 47.6 ... 19.5 .. 76.5 ... 25
660 .......... 27156 ... 6491 ... 50 ..... 39 .... 80 ..... 43
680 .......... 27157 ... 6492 ... 52.5 ... 70 .... 85 ..... 80
700 .......... 27158 ... 6493 ... 54.6 ... 78 .... 89.5 ... 137
720 .......... 27159 ... 6494 ... 56.5 ... 81.5 .. 93 ..... 150
740 .......... 27160 ... 6495 ... 59.5 ... 81.5 .. 95 ..... 155
760 .......... 27161 ... 6496 ... 62 ..... 72 .... 98 ..... 153
780 .......... 27162 ... 6497 ... 63 ..... 32 .... 99.5 ... 143
800 .......... 27163 ... 6498 ... 64 ..... 13.8 .. 100 .... 88
719.86 .......................... 57.5 ... 81.5 ... 93 .... 150