Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 09:15:54 on April 3, 2010
Entry number 315950
keyword=Start_Parity_Run_2550__CODA_Config=Prex_Run_type=Test,beam_current=0,beam_energy=1.063,beam_polarization=0,beam_raster=off,comment_text=stuff...,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=No Target, Empty
Beginning-of-Parity-run EPICS data for Run Number 2550 at Sat Apr 3 09:14:52 EDT 2010
CODA Configuration: Prex
Compton Run Number : 22440
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7456
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -58.9992
Wien BDL (Gcm) : -1348
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 37.247
Laser attenuation Hall A : 76
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 5.03297
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.968
Gun2: PC (PITA) NEG : 7.304
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0551
Pockels Cell Y Stage : -0.03735
Wager X Stage : 800
Wager Y Stage : 775
Hall A Slit Position : 35
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity : -0.00154814
Photodiode on table : 1719.3
Laser X position on QPD 1 : 967.314
Laser Y position on QPD 1 : 0.818991
Laser X position on QPD 2 : -732.299
Laser Y position on QPD 2 : 39.1493
QPD 1 sum : -0.0744675
QPD 2 sum : -0.136727
Position set point for adjustable
mirror 1 (either x or y) : -3485[c]
Position set point for adjustable
mirror 2 (either x or y) : -1975[c]
Laser minimum temperature (35.8) : 32.2
Laser temperature set point : +47.247
Polarisation in cavity : RIGHT
Reflection photodiode : 0.0799609
Gain of locking servo : 130
Tracking level (V) of locking servo : 0.7
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 9.23823
Calculated polarisation in cavity : 328.288
Photodiode 1 after Wollaston prism : 0.000382949
Photodiode 2 after Wollaston prism : -0.000204121
Step size for RHWP scan : 250
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.0534066
Left Arm Q1 momentum : 0.00136435
Left Arm Q1 gauss meter : 0.0002147
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.856
Left Arm Q2 momentum : 1.0631
Left Arm Q2 gauss meter : 0.24243
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 354.017
Left Arm D1 momentum : 1.06302
Left Arm D1 NMR : 0.393547
Left Arm Q3 power supply current : 569.825
Left Arm Q3 momentum : 1.06294
Left Arm Q3 gauss meter : -0.28753
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.185
Right Arm Q1 momentum : 1.06319
Right Arm Q1 gauss meter : -0.014583
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.454
Right Arm Q2 momentum : 1.06307
Right Arm Q2 gauss meter : 0.24182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.461
Right Arm D1 momentum : 1.06301
Right Arm D1 NMR : 0.39447
Right Arm Q3 power supply current : 573.629
Right Arm Q3 momentum : 1.06333
Right Arm Q3 gauss meter : 0.2565
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.46484
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.0117188
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.999303
Current on Unser monitor : 22.6895
Current on Upstream bcm : 1.9844
Current on Downstream bcm : 0.0142099
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00423083
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 3.82126
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 18
Raster Y width : 8
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00126953
HacL_HPE1313A:0_Ch58 : -0.258301
HacL_HPE1313A:0_Ch55 : 22.7051
HacL_HPE1313A:0_Ch54 : 0.0449219
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00849609
HacR_HPE1313A:0_Ch58 : -0.635254
HacR_HPE1313A:0_Ch55 : 21.4844
HacR_HPE1313A:0_Ch54 : -0.974121
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Pb Diamond #3
Encoder position : 26503736
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 14.6731
pressure fill bottle H2 : 14.699
pressure ballast H2 : 23.856
pressure exhaust H2 : 14.7356
cryogen input temp : 121.4
crogen return flow : 5.92622
JT valve setting : -0.0488281
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -1000.7
Lower Quartz : -1001.8
A_T Quartz : -1497.3
Upper Scint : -5.8
Lower Scint : -7.5
S0 A : -7.5
S0 B : -7.4
-----------------------------------------
PREX Det Encoder Positions
-----------------------------------------
Left Main Det x : 0.738281
Left Main Det y : 1.76025
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.76025
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.427
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
anatype fdbk
curmon bcm1
feedback PITA on 5 bcm1
feedback IA off 2 bcm1
feedback PZT off 20 bpm4b
PITAparam slope -1721
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Adcx_DAC_burp
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 0 10
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/PREX/runlistDB/addRun2runlist.pl -r 2550 -d '2010-04-03 09:07:22' -t 26503736 -s IN