User name jwexler
Log entry time 01:22:27 on April 4,2010
Entry number 316045
keyword=A_T detectors moved
All A_T detectors were swept about their full range of motion in order to map the encoder readbacks. Ranges were found, and the detectors were then moved and left such that they were at the -ve edge in y, and middle of the range in x. This corresponds to a position mid-distance from the target, and nearest to the beamline.