Log entry time 10:10:54 on April 4, 2010
Entry number 316138
keyword=Start_Parity_Run_2584__CODA_Config=Prex_Run_type=Calibration,beam_current=50,beam_energy=1.063,beam_polarization=0,beam_raster=on,comment_text=lumi HV adjust,dithering_magnet=on,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Thick C12
Beginning-of-Parity-run EPICS data for Run Number 2584 at Sun Apr 4 10:09:51 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22441
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7456
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -58.9992
Wien BDL (Gcm) : -1348
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 37.247
Laser attenuation Hall A : 132
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.89866
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.9
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.702
Gun2: PC (PITA) NEG : 8.57
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0551
Pockels Cell Y Stage : -0.03735
Wager X Stage : 800
Wager Y Stage : 775
Hall A Slit Position : -0.989258
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 84mW
Calculated power in cavity : 1430.08
Photodiode on table : 952.924
Laser X position on QPD 1 : 875.982
Laser Y position on QPD 1 : 2.16969
Laser X position on QPD 2 : -674.83
Laser Y position on QPD 2 : 162.913
QPD 1 sum : -3.87231
QPD 2 sum : -4.33132
Position set point for adjustable
mirror 1 (either x or y) : -3485[c]
Position set point for adjustable
mirror 2 (either x or y) : -1975[c]
Laser minimum temperature (35.8) : 32.2
Laser temperature set point : +47.027
Polarisation in cavity : LEFT
Reflection photodiode : 0.43887
Gain of locking servo : 130
Tracking level (V) of locking servo : 0.7
Slow locking signal sent to laser : 0.144662
Fast locking signal sent to laser : 3.09284
Calculated polarisation in cavity : 97.0272
Photodiode 1 after Wollaston prism : 3.05528
Photodiode 2 after Wollaston prism : 202.494
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.025
Left Arm Q1 momentum : 1.0628
Left Arm Q1 gauss meter : -0.04884
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.76
Left Arm Q2 momentum : 1.06288
Left Arm Q2 gauss meter : 0.2431
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.989
Left Arm D1 momentum : 1.06302
Left Arm D1 NMR : 0.393548
Left Arm Q3 power supply current : 569.783
Left Arm Q3 momentum : 1.06286
Left Arm Q3 gauss meter : -0.28749
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.078
Right Arm Q1 momentum : 1.063
Right Arm Q1 gauss meter : -0.014607
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.461
Right Arm Q2 momentum : 1.06309
Right Arm Q2 gauss meter : 0.2424
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.748
Right Arm D1 momentum : 1.06298
Right Arm D1 NMR : 0.394459
Right Arm Q3 power supply current : 573.599
Right Arm Q3 momentum : 1.06328
Right Arm Q3 gauss meter : 0.2564
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.46484
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.00244141
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 44.3038
Current on Unser monitor : 68.4061
Current on Upstream bcm : 39.8634
Current on Downstream bcm : 48.7442
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 54.1587
Tiefenbach Hall A energy : 1060.45
Tiefenbach Hall C energy : 5092.66
Delta(E)/E width (MV_AI_DXWID) : 3.78865
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 5108.41
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 18
Raster Y width : 8
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.272545
IPM1C12.YPOS : 0.112642
IPM1H04A.XPOS : -0.334183
IPM1H04A.YPOS : 0.988286
IPM1H04B.XPOS : 0.0810049
IPM1H04B.YPOS : 2.23407
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0.326955
Survey Y offset bpm12 : 0.130342
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00175781
HacL_HPE1313A:0_Ch58 : -0.256836
HacL_HPE1313A:0_Ch55 : 22.9492
HacL_HPE1313A:0_Ch54 : 0.0458984
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00859375
HacR_HPE1313A:0_Ch58 : -0.633301
HacR_HPE1313A:0_Ch55 : 21.6309
HacR_HPE1313A:0_Ch54 : -0.974121
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Thick Carbon
Encoder position : 17784412
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 14.7738
pressure fill bottle H2 : 14.8684
pressure ballast H2 : 24.1413
pressure exhaust H2 : 14.7707
cryogen input temp : 123.1
crogen return flow : 5.91202
JT valve setting : -0.0488281
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -860.8
Lower Quartz : -810.8
A_T Quartz : -998.3
Upper Scint : -5.8
Lower Scint : -7.5
S0 A : -9.8
S0 B : -7.4
-----------------------------------------
PREX Det Encoder Positions
-----------------------------------------
Left Main Det x : 0.737793
Left Main Det y : 1.76074
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.76123
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 0
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
anatype fdbk
curmon bcm3
feedback PITA on 5 bcm2
PITAparam slope -1721
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Adcx_DAC_burp
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 0 10
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/PREX/runlistDB/addRun2runlist.pl -r 2584 -d '2010-04-04 10:09:48' -t 17784412 -s IN