User name apar
Log entry time 14:52:07 on April 15, 2010
Entry number 317334
keyword=End_of_Parity_Run_2799__CODA_Config=Prex
************************************************
Run Number: 2799
End of Run Comment:
Run_type=Test,beam_current=0,beam_energy=1.063,beam_polarization=0,beam_raster=on,comment_text=test,dithering_magnet=off,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Thick C12
************************************************
End-of-Parity-run EPICS data for Run Number 2799 at Thu Apr 15 14:51:50 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 3.84 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 22531
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7456
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1193.9
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 5.11844
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 5.1
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.425
Gun2: PC (PITA) NEG : 8.829
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.05505
Pockels Cell Y Stage : -0.03725
Wager X Stage : 800
Wager Y Stage : 775
Hall A Slit Position : -0.989746
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity :
Photodiode on table : 834.712
Laser X position on QPD 1 : 830.386
Laser Y position on QPD 1 : 9.96329
Laser X position on QPD 2 : -827.098
Laser Y position on QPD 2 : 23.1876
QPD 1 sum : -0.599402
QPD 2 sum : -2.53311
Position set point for adjustable
mirror 1 (either x or y) : -3965[c]
Position set point for adjustable
mirror 2 (either x or y) : 1600[c]
Laser minimum temperature (35.8) : 32.2
Laser temperature set point : +47.070
Polarisation in cavity : LEFT
Reflection photodiode : 0.707441
Gain of locking servo : 120
Tracking level (V) of locking servo : 0.73
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -0.624428
Calculated polarisation in cavity : 98.3627
Photodiode 1 after Wollaston prism : 0.000398065
Photodiode 2 after Wollaston prism : 0.0482277
Step size for RHWP scan : 250
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : COMPTON_LASERT_RAMPDT --- Invalid channel name
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 581.971
Left Arm Q1 momentum : 1.0628
Left Arm Q1 gauss meter : -0.04881
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.807
Left Arm Q2 momentum : 1.06299
Left Arm Q2 gauss meter : 0.2423
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.889
Left Arm D1 momentum : 1.06303
Left Arm D1 NMR : 0.393551
Left Arm Q3 power supply current : 569.937
Left Arm Q3 momentum : 1.06315
Left Arm Q3 gauss meter : -0.28677
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.239
Right Arm Q1 momentum : 1.06329
Right Arm Q1 gauss meter : -0.014588
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.567
Right Arm Q2 momentum : 1.06333
Right Arm Q2 gauss meter : 0.24184
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.483
Right Arm D1 momentum : 1.06302
Right Arm D1 NMR : 0.394475
Right Arm Q3 power supply current : 573.429
Right Arm Q3 momentum : 1.06296
Right Arm Q3 gauss meter : 0.25597
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0166016
Left Arm Bottom VDC voltage : 0.0175781
Right Arm Top VDC voltage : -0.00634766
Right Arm Bottom VDC voltage : -0.0112305
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 4.34374
Current on Unser monitor : 24.9152
Current on Upstream bcm : 3.85858
Current on Downstream bcm : 4.82889
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 4.87782
Tiefenbach Hall A energy : 1060.57
Tiefenbach Hall C energy : 4085.03
Delta(E)/E width (MV_AI_DXWID) : 0.66119
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 4097.15
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 8
Raster Y width : 8
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.220597
IPM1C12.YPOS : -0.386721
IPM1H04A.XPOS : 0.413144
IPM1H04A.YPOS : -0.0878365
IPM1H04B.XPOS : 0.0582101
IPM1H04B.YPOS : 0.0542358
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0.220597
Survey Y offset bpm12 : -0.383656
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00180664
HacL_HPE1313A:0_Ch58 : -0.258789
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : 0.0415039
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00874023
HacR_HPE1313A:0_Ch58 : -0.634766
HacR_HPE1313A:0_Ch55 : 21.5332
HacR_HPE1313A:0_Ch54 : -0.978027
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 13395291
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 14.8791
pressure fill bottle H2 : 14.9035
pressure ballast H2 : 23.8499
pressure exhaust H2 : 14.6792
cryogen input temp : 208.9
crogen return flow : 8.07933
JT valve setting : 0.390625
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -830.6
Lower Quartz : -771.1
A_T Quartz : -998.3
Upper Scint : -5.8
Lower Scint : -20.5
S0 A : -7.5
S0 B : -7.4
-----------------------------------------
PREX Det Encoder Position
-----------------------------------------
Left Main Det x : 0.425781
Left Main Det y : 1.69727
Right Main Det x : HacH_DTC_HPE1313A:0_Ch10 --- Invalid channel name
Right Main Det y : 1.69678
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.443
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #2799
Was feedback on?