Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name R. Michaels
Log entry time 20:21:01 on April 26, 2010
Entry number 319672
This entry is a followup to: 319647
Followups:
keyword=re: bad cavities
I guess the bad cavities today are due to the low-current running and
that we forgot to restore the high-current gain settings and phases.
Regarding the problem we had Sunday in low-current mode: No signals
were seen in the counting DAQ. This was because the cable fell out
of the Fastbus. I think Ahmed has fixed it.
We should always check high-current with spot++. Plotting cavities
versus striplines with counting mode should show an ellipse.
(It's not a line because there's a phase.) If we don't get this
well-known result there is a problem with the cabling or with
the high-current setup. This is a basic checkout that should be
done before a Qsq measurement in the future.
A copy of this log entry has been emailed to: zahmed,mcnulty