• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 20:21:01 on April 26, 2010

    Entry number 319672

    This entry is a followup to: 319647

    Followups:

    keyword=re: bad cavities

    I guess the bad cavities today are due to the low-current running and
    that we forgot to restore the high-current gain settings and phases.
    
    Regarding the problem we had Sunday in low-current mode:  No signals
    were seen in the counting DAQ.  This was because the cable fell out
    of the Fastbus.  I think Ahmed has fixed it.
    
    We should always check high-current with spot++.  Plotting cavities
    versus striplines with counting mode should show an ellipse.
    (It's not a line because there's a phase.) If we don't get this
    well-known result there is a problem with the cabling or with
    the high-current setup.  This is a basic checkout that should be
    done before a Qsq measurement in the future.
    


    A copy of this log entry has been emailed to: zahmed,mcnulty