NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 22:52:46 on April 26, 2010
Entry number 319710
keyword=Start_Parity_Run_3194__CODA_Config=Prex_Run_type=Test,beam_current=50,beam_energy=1.063,beam_polarization=0,beam_raster=on,comment_text=oversampling 4, current ramp,dithering_magnet=on,dithering_magnets=,leftarm_p=1.063,leftarm_theta=5,parity_feedback=on,parity_ihwp=in,rightarm_p=1.063,rightarm_theta=5,target_fanspeed=0 Hz,target_type=Thick C12
Beginning-of-Parity-run EPICS data for Run Number 3194 at Mon Apr 26 22:51:49 EDT 2010
CODA Configuration: Prex
# Timing board information: # Integrate Time = 0.87 ms, Ramp Delay = 0.00 us oversamp 4
Compton Run Number : 22739
-----------------------------------------
Wien angle (Vertical) : 88.8235
Wien Vertical BDL (Gcm) : 2152.7
Wien HV Polarity : OFF
Wien electrode Voltage : 55.48
Wien angle (Solenoids) : 90.7456
Wien BDL (First Solenoid) (Gcm) : 876.345
Wien BDL (Second Solenoid) (Gcm) : 876.346
Wien angle (Horizontal) : -51.9996
Wien BDL (Gcm) : -1193.9
Wien HV Polarity (Horizontal) : ON
Wien electrode Voltage (Horizontal) : 32.828
Laser attenuation Hall A : 169
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 2350
IA Cell Setpoint Hall A : 4.96
IA Cell Setpoint Hall B : 4.94505
IA Cell Setpoint Hall C : 5
PZT X Setpoint Hall A : 4
PZT Y Setpoint Hall A : 4
PZT X Setpoint Common : 4.95
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 6.236
Gun2: PC (PITA) NEG : 9.018
Pockels Cell ON/OFF : ON
Pockels Cell X Stage : -0.0549
Pockels Cell Y Stage : -0.0373
Wager X Stage : 800
Wager Y Stage : 775
Hall A Slit Position : -0.98291
Helicity Clock Set : Free Clock
Helicity Delay Set : 16 windows
Helicity Pattern Set : Octet
Helicity Clock Read : Free Clock
Helicity Settle Read : 100
Helicity Stable Read : 4067
Helicity Delay Read : 16 windows
Helicity Pattern Read : Octet
Helicity Frequency : 239.981
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr 79mW
Calculated power in cavity : 0.0523294
Photodiode on table : 771.44
Laser X position on QPD 1 : 856.841
Laser Y position on QPD 1 : 5.18724
Laser X position on QPD 2 : -509.458
Laser Y position on QPD 2 : 113.73
QPD 1 sum : -1.61753
QPD 2 sum : -1.87389
Position set point for adjustable
mirror 1 (either x or y) : -555[c]
Position set point for adjustable
mirror 2 (either x or y) : -4185[c]
Laser minimum temperature (35.8) : 32.201
Laser temperature set point : +47.147
Polarisation in cavity : LEFT
Reflection photodiode : 0.664713
Gain of locking servo : 130
Tracking level (V) of locking servo : 0.64
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -9.05878
Calculated polarisation in cavity : 2.48427
Photodiode 1 after Wollaston prism : 0.00404112
Photodiode 2 after Wollaston prism : 0.0038452
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Speed of laser temp slow ramp up : 0.015
Speed of laser temp slow ramp down : 0.015
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 582.025
Left Arm Q1 momentum : 1.0628
Left Arm Q1 gauss meter : -0.04869
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 461.862
Left Arm Q2 momentum : 1.06311
Left Arm Q2 gauss meter : 0.2431
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 353.904
Left Arm D1 momentum : 1.063
Left Arm D1 NMR : 0.393541
Left Arm Q3 power supply current : 569.792
Left Arm Q3 momentum : 1.06288
Left Arm Q3 gauss meter : -0.28755
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 582.078
Right Arm Q1 momentum : 1.063
Right Arm Q1 gauss meter : -0.014267
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 463.538
Right Arm Q2 momentum : 1.06326
Right Arm Q2 gauss meter : 0.2424
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 364.475
Right Arm D1 momentum : 1.06299
Right Arm D1 NMR : 0.394462
Right Arm Q3 power supply current : 573.582
Right Arm Q3 momentum : 1.06324
Right Arm Q3 gauss meter : 0.2564
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents & Voltages
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.00683594
Right Arm Bottom VDC voltage : -0.012207
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 50.3186
Current on Unser monitor : 71.3576
Current on Upstream bcm : 50.9658
Current on Downstream bcm : 49.6714
Upstream Cavity Coefficient : 52.95
Downstream Cavity Coefficient : 44.77
Current on IBC0L02 (source) : 49.5186
Tiefenbach Hall A energy : 1060.52
Tiefenbach Hall C energy : 4085.03
Delta(E)/E width (MV_AI_DXWID) : 4.9393
MBSY1c Hall A Beam energy : 1061.34
MBSY3c Hall C Beam energy : 4097.15
MBSY1c magnet current (amp) : 43.916
MBSY1c Bdl : 264859
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 17
Raster Y width : 7
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0103937
IPM1C12.YPOS : -0.139337
IPM1H04A.XPOS : -0.0613437
IPM1H04A.YPOS : -0.00193611
IPM1H04B.XPOS : 0.0384077
IPM1H04B.YPOS : 0.994712
Survey X offset bpm4A : 0.24
Survey Y offset bpm4A : 0.36
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : 1
Survey X offset bpm12 : 0.0103937
Survey Y offset bpm12 : -0.139337
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
Left Arm Collimator
-----------------------------------------
Left Arm Collimator : 0.00229492
HacL_HPE1313A:0_Ch58 : -0.274414
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : 0.0141602
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----------------------------------------
Right Arm Collimator
-----------------------------------------
Right Arm Collimator : -0.00600586
HacR_HPE1313A:0_Ch58 : -0.653809
HacR_HPE1313A:0_Ch55 : 21.4844
HacR_HPE1313A:0_Ch54 : -0.98877
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Clear
Encoder position : 17784412
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 119.99
temperature loop 1-2 : 119.99
temperature loop 1-3 : 119.99
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 0
temperature loop 3-2 : 0
temperature loop 3-3 : 0
pressure fill target H2 : 14.7936
pressure fill bottle H2 : 14.1665
pressure ballast H2 : 23.8453
pressure exhaust H2 : 14.583
cryogen input temp : 210.4
crogen return flow : 7.54576
JT valve setting : 0.439453
-----------------------------------------
PREX Left arm Det/Scint/S0 HV
-----------------------------------------
Upper Quartz : -975.2
Lower Quartz : -865.8
A_T Quartz : -1097.5
Upper Scint : -5.8
Lower Scint : -22
S0 A : -19.7
S0 B : -21.2
-----------------------------------------
PREX Det Encoder Positions
-----------------------------------------
Left Main Det x : 1.09131
Left Main Det y : 1.86719
Right Main Det x : 0.441895
Right Main Det y : 1.95703
-----------------------------------------
PREX A_T Encoder Positions
-----------------------------------------
Left A_T Det x : 3.12305
Left A_T Det y : 1.80273
Right A_T Det x : 1.30811
Right A_T Det y : 3.37598
-----------------------------------------
PREX Septum Currents
-----------------------------------------
Current Setpoint(Amps) : 729
Current Readback(Amps) : 725.411
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
anatype fdbk
curmon bcm1
feedback PITA on 8 bcm1
PITAparam slope -800
feedback IA off 2 bcm1
feedback PZT off 20 bpm4b
ncuts 6
cutnames Low_beam Beam_burp Evt_seq Pair_seq Startup Adcx_DAC_burp
extlo 10 10 25 25 0 10
exthi 1200 40 25 25 0 10
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/PREX/runlistDB/addRun2runlist.pl -r 3194 -d '2010-04-26 22:51:44' -t 17784412 -s IN